Deliver to United Kingdom
0
Products Found: 46
Showing Results For: Cooled Incubators

Cooled Incubators



New Items
New
IPP260ecoplus, Omnilab

IPP260ecoplus, Omnilab

Heating and cooling seamlessly with one system thanks to Peltier technology. In this respect, cooled incubators IPPeco not only contribute to climate protection, but also achieve an additional decrease in operating costs of up 90 % compared to compressor technology. Outstanding control precision and extremely small fluctuations. Extremely quiet, space-saving and vibration-free due to the fact that no compressor is required. Peltier cooled incubators IPPeco / IPPecoplus can also be applied in entomology. No condensation in the interior chamber: due to the closed Peltier cooling system, no outside air is exchanged. Formation of condensation during the cooling process takes place on the outside heat sink. In addition, the fans integrated in the Peltier elements ensure a rapid transport of energy as well as an optimal temperature distribution. - LED light module for model sizes 110 to 750 (optional): dimmable LED light in 3 alternative colour temperatures (coldwhite or warmwhite light or cold-white plus warm-white light, dimmable in 10 % steps). - Acc. to DIN 12880:2007-05, EN 61010-1 (IEC 61010-1), 61010-2-010. AtmoCONTROL - control and logging software For direct setting parameters as well as process time. Fast and easy programming of complex processes via AtmoCONTROL by means of the mouse or touchpad on the notebook. - Reading out, managing and organising the data logger. - Saving the log memory in various formats. - Online monitoring of up to 32 connected appliances. - Optical alarms when the alarm limits individually set at the ControlCOCKPIT are exceeded. - Automatic alarm to one or several e-mail addresses. - TwinDISPLAY: ControlCOCKPIT with 2 TFT colour graphical displays. - 2 Pt100 sensors DIN class A in a 4-wire circuit for mutual monitoring, taking over functions in case of an error. - HeatBALANCE function for application specific adjustment of heat output distribution (balance) between the upper and lower heating groups in an adjustment range between - 50 and + 50 % (not valid for IPP110plus). - AtmoCONTROL software on an USB stick for programming, managing and transferring programmes via ethernet interface or USB port. - Intuitive programming and archiving of ramps and programme sequences. - ControlCOCKPIT with USB port for uploading programmes, reading out protocol logs, activating the User-ID function. - Displaying of already logged protocol data on the ControlCOCKPIT (max. 10000 values correspond to approx. 1 week). - Ethernet interface on the rear of the appliance for reading out the protocol log and for uploading and implementing programmes and for online logging. - Multiple overtemperature protection: electronic temperature monitoring TWW (protection class 3.3) and mechanical temperature limiter TB (protection class 1) acc. to. DIN 12880, AutoSAFETY automatically adjusts to the set value within a freely adjustable tolerance range. Setting individual MIN / MAX values for over / undertemperature alarm. Heating and cooling seamlessly with one system thanks to Peltier technology. In this respect, cooled incubators IPPeco not only contribute to climate protection, but also achieve an additional decrease in operating costs of up 90 % compared to compressor technology. Outstanding control precision and extremely small fluctuations. Extremely quiet, space-saving and vibration-free due to the fact that no compressor is required. Peltier cooled incubators IPPeco / IPPecoplus can also be applied in entomology. No condensation in the interior chamber: due to the closed Peltier cooling system, no outside air is exchanged. Formation of condensation during the cooling process takes place on the outside heat sink. In addition, the fans integrated in the Peltier elements ensure a rapid transport of energy as well as an optimal temperature distribution. - LED light module for model sizes 110 to 750 (optional): dimmable LED light in 3 alternative colour temperatures (coldwhite or warmwhite light or cold-white plus warm-white light, dimmable in 10 % steps). - Acc. to DIN 12880:2007-05, EN 61010-1 (IEC 61010-1), 61010-2-010. AtmoCONTROL - control and logging software For direct setting parameters as well as process time. Fast and easy programming of complex processes via AtmoCONTROL by means of the mouse or touchpad on the notebook. - Reading out, managing and organising the data logger. - Saving the log memory in various formats. - Online monitoring of up to 32 connected appliances. - Optical alarms when the alarm limits individually set at the ControlCOCKPIT are exceeded. - Automatic alarm to one or several e-mail addresses. - TwinDISPLAY: ControlCOCKPIT with 2 TFT colour graphical displays. - 2 Pt100 sensors DIN class A in a 4-wire circuit for mutual monitoring, taking over functions in case of an error. - HeatBALANCE function for application specific adjustment of heat output distribution (balance) between the upper and lower heating groups in an adjustment range between - 50 and + 50 % (not valid for IPP110plus). - AtmoCONTROL software on an USB stick for programming, managing and transferring programmes via ethernet interface or USB port. - Intuitive programming and archiving of ramps and programme sequences. - ControlCOCKPIT with USB port for uploading programmes, reading out protocol logs, activating the User-ID function. - Displaying of already logged protocol data on the ControlCOCKPIT (max. 10000 values correspond to approx. 1 week). - Ethernet interface on the rear of the appliance for reading out the protocol log and for uploading and implementing programmes and for online logging. - Multiple overtemperature protection: electronic temperature monitoring TWW (protection class 3.3) and mechanical temperature limiter TB (protection class 1) acc. to. DIN 12880, AutoSAFETY automatically adjusts to the set value within a freely adjustable tolerance range. Setting individual MIN / MAX values for over / undertemperature alarm.

Product Detail
New
MIR-554-PE, Omnilab

MIR-554-PE, Omnilab

Panasonic´s MIR cooled series incubators provide a temperature range of - 10 to 60 °C. Incorporating an 8-bit microcomputer, these incubators control the heater and compressor within a precise ± 0.2 °C and ± 1.5 °C range, respectively. - Programmable 3-step operation with microcomputer control: combining flexible temperature and time control, a maximum 3-step plus constant operation or max. 3-step repeating operation can be programmed according to the experimentation requirements. The one-step setting time ranges from 0.0 to 99.5 h in increments of 30 min. A program can be set to repeat for a minimum of once up to a maximum of 99 times. Ideal for experimentation during night time or holidays, experimentation that requires settings to be changed, and microorganism culture and preservation. Constant operation mode without step operation is also available. - Microprocessor control with feed forward function: SANYO cooled incubators incorporate a high precision microprocessor temperature control combined with a heater PID and compressor ON-OFF system. This system has a feed forward function that monitors the operating conditions of the compressor, ensuring accurate temperature control of the chamber. - Energy savings: because heater output and compressor on / off are microprocessor controlled, optimum automatic operation according to ambient temperature and fluctuation of chamber load is possible, resulting in high-energy savings. - Foamed-in-place rigid polyurethane insulation. - Triple-pane glass observation window plus programmable 15 W fluorescent lamp. - Automatic setting temperature alarm. - Independent over-temperature protection device. - Programmed memory backup mechanism: should the power source be interrupted due to power failure or other event, programmed data remains stored in memory for approx. 5 h. When the power source is restored, operation can be continued according to the predetermined program. - Automatic return buzzer switch. - Key lock switch. - Auto return mechanism: this mechanism automatically returns the chamber temperature indicator to its normal indication when the control key is not operated for approx. 90 s at each setting mode. - Trouble monitor (self diagnostic function): should a malfunction occur, the location of the malfunction can be indicated, allowing quick operator response. - Graphic display with data log function for 2 weeks, password protection programmable for up to 12 steps, 10 programs max. 99 cycles, real-time clock and sequence control. - Door rabbet changeable. Panasonic´s MIR cooled series incubators provide a temperature range of - 10 to 60 °C. Incorporating an 8-bit microcomputer, these incubators control the heater and compressor within a precise ± 0.2 °C and ± 1.5 °C range, respectively. - Programmable 3-step operation with microcomputer control: combining flexible temperature and time control, a maximum 3-step plus constant operation or max. 3-step repeating operation can be programmed according to the experimentation requirements. The one-step setting time ranges from 0.0 to 99.5 h in increments of 30 min. A program can be set to repeat for a minimum of once up to a maximum of 99 times. Ideal for experimentation during night time or holidays, experimentation that requires settings to be changed, and microorganism culture and preservation. Constant operation mode without step operation is also available. - Microprocessor control with feed forward function: SANYO cooled incubators incorporate a high precision microprocessor temperature control combined with a heater PID and compressor ON-OFF system. This system has a feed forward function that monitors the operating conditions of the compressor, ensuring accurate temperature control of the chamber. - Energy savings: because heater output and compressor on / off are microprocessor controlled, optimum automatic operation according to ambient temperature and fluctuation of chamber load is possible, resulting in high-energy savings. - Foamed-in-place rigid polyurethane insulation. - Triple-pane glass observation window plus programmable 15 W fluorescent lamp. - Automatic setting temperature alarm. - Independent over-temperature protection device. - Programmed memory backup mechanism: should the power source be interrupted due to power failure or other event, programmed data remains stored in memory for approx. 5 h. When the power source is restored, operation can be continued according to the predetermined program. - Automatic return buzzer switch. - Key lock switch. - Auto return mechanism: this mechanism automatically returns the chamber temperature indicator to its normal indication when the control key is not operated for approx. 90 s at each setting mode. - Trouble monitor (self diagnostic function): should a malfunction occur, the location of the malfunction can be indicated, allowing quick operator response. - Graphic display with data log function for 2 weeks, password protection programmable for up to 12 steps, 10 programs max. 99 cycles, real-time clock and sequence control. - Door rabbet changeable.

Product Detail
New
IPP1400eco, Omnilab

IPP1400eco, Omnilab

Heating and cooling seamlessly with one system thanks to Peltier technology. In this respect, cooled incubators IPPeco not only contribute to climate protection, but also achieve an additional decrease in operating costs of up 90 % compared to compressor technology. Outstanding control precision and extremely small fluctuations. Extremely quiet, space-saving and vibration-free due to the fact that no compressor is required. Peltier cooled incubators IPPeco / IPPecoplus can also be applied in entomology. No condensation in the interior chamber: due to the closed Peltier cooling system, no outside air is exchanged. Formation of condensation during the cooling process takes place on the outside heat sink. In addition, the fans integrated in the Peltier elements ensure a rapid transport of energy as well as an optimal temperature distribution. - LED light module for model sizes 110 to 750 (optional): dimmable LED light in 3 alternative colour temperatures (coldwhite or warmwhite light or cold-white plus warm-white light, dimmable in 10 % steps). - Acc. to DIN 12880:2007-05, EN 61010-1 (IEC 61010-1), 61010-2-010. AtmoCONTROL - control and logging software For direct setting parameters as well as process time. Fast and easy programming of complex processes via AtmoCONTROL by means of the mouse or touchpad on the notebook. - Reading out, managing and organising the data logger. - Saving the log memory in various formats. - Online monitoring of up to 32 connected appliances. - Optical alarms when the alarm limits individually set at the ControlCOCKPIT are exceeded. - Automatic alarm to one or several e-mail addresses. - SingleDISPLAY: ControlCOCKPIT with one TFT colour graphical display. - One temperature sensor Pt100 DIN class A in a 4-wire circuit. - AtmoCONTROL software for reading out, managing and organising the data logger via ethernet interface (temporary trial version can be downloaded). USB stick with AtmoCONTROL software available as accessory on demand. - Ethernet interface on the rear of the appliance for reading out the protocol log. - Double overtemperature protection: electronic temperature monitoring with freely adjustable monitoring temperature, mechanical temperature limiter TB acc. to DIN 12880. Heating and cooling seamlessly with one system thanks to Peltier technology. In this respect, cooled incubators IPPeco not only contribute to climate protection, but also achieve an additional decrease in operating costs of up 90 % compared to compressor technology. Outstanding control precision and extremely small fluctuations. Extremely quiet, space-saving and vibration-free due to the fact that no compressor is required. Peltier cooled incubators IPPeco / IPPecoplus can also be applied in entomology. No condensation in the interior chamber: due to the closed Peltier cooling system, no outside air is exchanged. Formation of condensation during the cooling process takes place on the outside heat sink. In addition, the fans integrated in the Peltier elements ensure a rapid transport of energy as well as an optimal temperature distribution. - LED light module for model sizes 110 to 750 (optional): dimmable LED light in 3 alternative colour temperatures (coldwhite or warmwhite light or cold-white plus warm-white light, dimmable in 10 % steps). - Acc. to DIN 12880:2007-05, EN 61010-1 (IEC 61010-1), 61010-2-010. AtmoCONTROL - control and logging software For direct setting parameters as well as process time. Fast and easy programming of complex processes via AtmoCONTROL by means of the mouse or touchpad on the notebook. - Reading out, managing and organising the data logger. - Saving the log memory in various formats. - Online monitoring of up to 32 connected appliances. - Optical alarms when the alarm limits individually set at the ControlCOCKPIT are exceeded. - Automatic alarm to one or several e-mail addresses. - SingleDISPLAY: ControlCOCKPIT with one TFT colour graphical display. - One temperature sensor Pt100 DIN class A in a 4-wire circuit. - AtmoCONTROL software for reading out, managing and organising the data logger via ethernet interface (temporary trial version can be downloaded). USB stick with AtmoCONTROL software available as accessory on demand. - Ethernet interface on the rear of the appliance for reading out the protocol log. - Double overtemperature protection: electronic temperature monitoring with freely adjustable monitoring temperature, mechanical temperature limiter TB acc. to DIN 12880.

Product Detail
New
IPP55plus, Omnilab

IPP55plus, Omnilab

Heating and cooling seamlessly with one system thanks to Peltier technology. In this respect, cooled incubators IPPeco not only contribute to climate protection, but also achieve an additional decrease in operating costs of up 90 % compared to compressor technology. Outstanding control precision and extremely small fluctuations. Extremely quiet, space-saving and vibration-free due to the fact that no compressor is required. Peltier cooled incubators IPPeco / IPPecoplus can also be applied in entomology. No condensation in the interior chamber: due to the closed Peltier cooling system, no outside air is exchanged. Formation of condensation during the cooling process takes place on the outside heat sink. In addition, the fans integrated in the Peltier elements ensure a rapid transport of energy as well as an optimal temperature distribution. - LED light module for model sizes 110 to 750 (optional): dimmable LED light in 3 alternative colour temperatures (coldwhite or warmwhite light or cold-white plus warm-white light, dimmable in 10 % steps). - Acc. to DIN 12880:2007-05, EN 61010-1 (IEC 61010-1), 61010-2-010. AtmoCONTROL - control and logging software For direct setting parameters as well as process time. Fast and easy programming of complex processes via AtmoCONTROL by means of the mouse or touchpad on the notebook. - Reading out, managing and organising the data logger. - Saving the log memory in various formats. - Online monitoring of up to 32 connected appliances. - Optical alarms when the alarm limits individually set at the ControlCOCKPIT are exceeded. - Automatic alarm to one or several e-mail addresses. - TwinDISPLAY: ControlCOCKPIT with 2 TFT colour graphical displays. - 2 Pt100 sensors DIN class A in a 4-wire circuit for mutual monitoring, taking over functions in case of an error. - HeatBALANCE function for application specific adjustment of heat output distribution (balance) between the upper and lower heating groups in an adjustment range between - 50 and + 50 % (not valid for IPP110plus). - AtmoCONTROL software on an USB stick for programming, managing and transferring programmes via ethernet interface or USB port. - Intuitive programming and archiving of ramps and programme sequences. - ControlCOCKPIT with USB port for uploading programmes, reading out protocol logs, activating the User-ID function. - Displaying of already logged protocol data on the ControlCOCKPIT (max. 10000 values correspond to approx. 1 week). - Ethernet interface on the rear of the appliance for reading out the protocol log and for uploading and implementing programmes and for online logging. - Multiple overtemperature protection: electronic temperature monitoring TWW (protection class 3.3) and mechanical temperature limiter TB (protection class 1) acc. to. DIN 12880, AutoSAFETY automatically adjusts to the set value within a freely adjustable tolerance range. Setting individual MIN / MAX values for over / undertemperature alarm. Heating and cooling seamlessly with one system thanks to Peltier technology. In this respect, cooled incubators IPPeco not only contribute to climate protection, but also achieve an additional decrease in operating costs of up 90 % compared to compressor technology. Outstanding control precision and extremely small fluctuations. Extremely quiet, space-saving and vibration-free due to the fact that no compressor is required. Peltier cooled incubators IPPeco / IPPecoplus can also be applied in entomology. No condensation in the interior chamber: due to the closed Peltier cooling system, no outside air is exchanged. Formation of condensation during the cooling process takes place on the outside heat sink. In addition, the fans integrated in the Peltier elements ensure a rapid transport of energy as well as an optimal temperature distribution. - LED light module for model sizes 110 to 750 (optional): dimmable LED light in 3 alternative colour temperatures (coldwhite or warmwhite light or cold-white plus warm-white light, dimmable in 10 % steps). - Acc. to DIN 12880:2007-05, EN 61010-1 (IEC 61010-1), 61010-2-010. AtmoCONTROL - control and logging software For direct setting parameters as well as process time. Fast and easy programming of complex processes via AtmoCONTROL by means of the mouse or touchpad on the notebook. - Reading out, managing and organising the data logger. - Saving the log memory in various formats. - Online monitoring of up to 32 connected appliances. - Optical alarms when the alarm limits individually set at the ControlCOCKPIT are exceeded. - Automatic alarm to one or several e-mail addresses. - TwinDISPLAY: ControlCOCKPIT with 2 TFT colour graphical displays. - 2 Pt100 sensors DIN class A in a 4-wire circuit for mutual monitoring, taking over functions in case of an error. - HeatBALANCE function for application specific adjustment of heat output distribution (balance) between the upper and lower heating groups in an adjustment range between - 50 and + 50 % (not valid for IPP110plus). - AtmoCONTROL software on an USB stick for programming, managing and transferring programmes via ethernet interface or USB port. - Intuitive programming and archiving of ramps and programme sequences. - ControlCOCKPIT with USB port for uploading programmes, reading out protocol logs, activating the User-ID function. - Displaying of already logged protocol data on the ControlCOCKPIT (max. 10000 values correspond to approx. 1 week). - Ethernet interface on the rear of the appliance for reading out the protocol log and for uploading and implementing programmes and for online logging. - Multiple overtemperature protection: electronic temperature monitoring TWW (protection class 3.3) and mechanical temperature limiter TB (protection class 1) acc. to. DIN 12880, AutoSAFETY automatically adjusts to the set value within a freely adjustable tolerance range. Setting individual MIN / MAX values for over / undertemperature alarm.

Product Detail
New
IPP260eco, Omnilab

IPP260eco, Omnilab

Heating and cooling seamlessly with one system thanks to Peltier technology. In this respect, cooled incubators IPPeco not only contribute to climate protection, but also achieve an additional decrease in operating costs of up 90 % compared to compressor technology. Outstanding control precision and extremely small fluctuations. Extremely quiet, space-saving and vibration-free due to the fact that no compressor is required. Peltier cooled incubators IPPeco / IPPecoplus can also be applied in entomology. No condensation in the interior chamber: due to the closed Peltier cooling system, no outside air is exchanged. Formation of condensation during the cooling process takes place on the outside heat sink. In addition, the fans integrated in the Peltier elements ensure a rapid transport of energy as well as an optimal temperature distribution. - LED light module for model sizes 110 to 750 (optional): dimmable LED light in 3 alternative colour temperatures (coldwhite or warmwhite light or cold-white plus warm-white light, dimmable in 10 % steps). - Acc. to DIN 12880:2007-05, EN 61010-1 (IEC 61010-1), 61010-2-010. AtmoCONTROL - control and logging software For direct setting parameters as well as process time. Fast and easy programming of complex processes via AtmoCONTROL by means of the mouse or touchpad on the notebook. - Reading out, managing and organising the data logger. - Saving the log memory in various formats. - Online monitoring of up to 32 connected appliances. - Optical alarms when the alarm limits individually set at the ControlCOCKPIT are exceeded. - Automatic alarm to one or several e-mail addresses. - SingleDISPLAY: ControlCOCKPIT with one TFT colour graphical display. - One temperature sensor Pt100 DIN class A in a 4-wire circuit. - AtmoCONTROL software for reading out, managing and organising the data logger via ethernet interface (temporary trial version can be downloaded). USB stick with AtmoCONTROL software available as accessory on demand. - Ethernet interface on the rear of the appliance for reading out the protocol log. - Double overtemperature protection: electronic temperature monitoring with freely adjustable monitoring temperature, mechanical temperature limiter TB acc. to DIN 12880. Heating and cooling seamlessly with one system thanks to Peltier technology. In this respect, cooled incubators IPPeco not only contribute to climate protection, but also achieve an additional decrease in operating costs of up 90 % compared to compressor technology. Outstanding control precision and extremely small fluctuations. Extremely quiet, space-saving and vibration-free due to the fact that no compressor is required. Peltier cooled incubators IPPeco / IPPecoplus can also be applied in entomology. No condensation in the interior chamber: due to the closed Peltier cooling system, no outside air is exchanged. Formation of condensation during the cooling process takes place on the outside heat sink. In addition, the fans integrated in the Peltier elements ensure a rapid transport of energy as well as an optimal temperature distribution. - LED light module for model sizes 110 to 750 (optional): dimmable LED light in 3 alternative colour temperatures (coldwhite or warmwhite light or cold-white plus warm-white light, dimmable in 10 % steps). - Acc. to DIN 12880:2007-05, EN 61010-1 (IEC 61010-1), 61010-2-010. AtmoCONTROL - control and logging software For direct setting parameters as well as process time. Fast and easy programming of complex processes via AtmoCONTROL by means of the mouse or touchpad on the notebook. - Reading out, managing and organising the data logger. - Saving the log memory in various formats. - Online monitoring of up to 32 connected appliances. - Optical alarms when the alarm limits individually set at the ControlCOCKPIT are exceeded. - Automatic alarm to one or several e-mail addresses. - SingleDISPLAY: ControlCOCKPIT with one TFT colour graphical display. - One temperature sensor Pt100 DIN class A in a 4-wire circuit. - AtmoCONTROL software for reading out, managing and organising the data logger via ethernet interface (temporary trial version can be downloaded). USB stick with AtmoCONTROL software available as accessory on demand. - Ethernet interface on the rear of the appliance for reading out the protocol log. - Double overtemperature protection: electronic temperature monitoring with freely adjustable monitoring temperature, mechanical temperature limiter TB acc. to DIN 12880.

Product Detail
New
IPP110ecoplus, Omnilab

IPP110ecoplus, Omnilab

Heating and cooling seamlessly with one system thanks to Peltier technology. In this respect, cooled incubators IPPeco not only contribute to climate protection, but also achieve an additional decrease in operating costs of up 90 % compared to compressor technology. Outstanding control precision and extremely small fluctuations. Extremely quiet, space-saving and vibration-free due to the fact that no compressor is required. Peltier cooled incubators IPPeco / IPPecoplus can also be applied in entomology. No condensation in the interior chamber: due to the closed Peltier cooling system, no outside air is exchanged. Formation of condensation during the cooling process takes place on the outside heat sink. In addition, the fans integrated in the Peltier elements ensure a rapid transport of energy as well as an optimal temperature distribution. - LED light module for model sizes 110 to 750 (optional): dimmable LED light in 3 alternative colour temperatures (coldwhite or warmwhite light or cold-white plus warm-white light, dimmable in 10 % steps). - Acc. to DIN 12880:2007-05, EN 61010-1 (IEC 61010-1), 61010-2-010. AtmoCONTROL - control and logging software For direct setting parameters as well as process time. Fast and easy programming of complex processes via AtmoCONTROL by means of the mouse or touchpad on the notebook. - Reading out, managing and organising the data logger. - Saving the log memory in various formats. - Online monitoring of up to 32 connected appliances. - Optical alarms when the alarm limits individually set at the ControlCOCKPIT are exceeded. - Automatic alarm to one or several e-mail addresses. - TwinDISPLAY: ControlCOCKPIT with 2 TFT colour graphical displays. - 2 Pt100 sensors DIN class A in a 4-wire circuit for mutual monitoring, taking over functions in case of an error. - HeatBALANCE function for application specific adjustment of heat output distribution (balance) between the upper and lower heating groups in an adjustment range between - 50 and + 50 % (not valid for IPP110plus). - AtmoCONTROL software on an USB stick for programming, managing and transferring programmes via ethernet interface or USB port. - Intuitive programming and archiving of ramps and programme sequences. - ControlCOCKPIT with USB port for uploading programmes, reading out protocol logs, activating the User-ID function. - Displaying of already logged protocol data on the ControlCOCKPIT (max. 10000 values correspond to approx. 1 week). - Ethernet interface on the rear of the appliance for reading out the protocol log and for uploading and implementing programmes and for online logging. - Multiple overtemperature protection: electronic temperature monitoring TWW (protection class 3.3) and mechanical temperature limiter TB (protection class 1) acc. to. DIN 12880, AutoSAFETY automatically adjusts to the set value within a freely adjustable tolerance range. Setting individual MIN / MAX values for over / undertemperature alarm. Heating and cooling seamlessly with one system thanks to Peltier technology. In this respect, cooled incubators IPPeco not only contribute to climate protection, but also achieve an additional decrease in operating costs of up 90 % compared to compressor technology. Outstanding control precision and extremely small fluctuations. Extremely quiet, space-saving and vibration-free due to the fact that no compressor is required. Peltier cooled incubators IPPeco / IPPecoplus can also be applied in entomology. No condensation in the interior chamber: due to the closed Peltier cooling system, no outside air is exchanged. Formation of condensation during the cooling process takes place on the outside heat sink. In addition, the fans integrated in the Peltier elements ensure a rapid transport of energy as well as an optimal temperature distribution. - LED light module for model sizes 110 to 750 (optional): dimmable LED light in 3 alternative colour temperatures (coldwhite or warmwhite light or cold-white plus warm-white light, dimmable in 10 % steps). - Acc. to DIN 12880:2007-05, EN 61010-1 (IEC 61010-1), 61010-2-010. AtmoCONTROL - control and logging software For direct setting parameters as well as process time. Fast and easy programming of complex processes via AtmoCONTROL by means of the mouse or touchpad on the notebook. - Reading out, managing and organising the data logger. - Saving the log memory in various formats. - Online monitoring of up to 32 connected appliances. - Optical alarms when the alarm limits individually set at the ControlCOCKPIT are exceeded. - Automatic alarm to one or several e-mail addresses. - TwinDISPLAY: ControlCOCKPIT with 2 TFT colour graphical displays. - 2 Pt100 sensors DIN class A in a 4-wire circuit for mutual monitoring, taking over functions in case of an error. - HeatBALANCE function for application specific adjustment of heat output distribution (balance) between the upper and lower heating groups in an adjustment range between - 50 and + 50 % (not valid for IPP110plus). - AtmoCONTROL software on an USB stick for programming, managing and transferring programmes via ethernet interface or USB port. - Intuitive programming and archiving of ramps and programme sequences. - ControlCOCKPIT with USB port for uploading programmes, reading out protocol logs, activating the User-ID function. - Displaying of already logged protocol data on the ControlCOCKPIT (max. 10000 values correspond to approx. 1 week). - Ethernet interface on the rear of the appliance for reading out the protocol log and for uploading and implementing programmes and for online logging. - Multiple overtemperature protection: electronic temperature monitoring TWW (protection class 3.3) and mechanical temperature limiter TB (protection class 1) acc. to. DIN 12880, AutoSAFETY automatically adjusts to the set value within a freely adjustable tolerance range. Setting individual MIN / MAX values for over / undertemperature alarm.

Product Detail
New
IPP12200eco, Omnilab

IPP12200eco, Omnilab

Heating and cooling seamlessly with one system thanks to Peltier technology. In this respect, cooled incubators IPPeco not only contribute to climate protection, but also achieve an additional decrease in operating costs of up 90 % compared to compressor technology. Outstanding control precision and extremely small fluctuations. Extremely quiet, space-saving and vibration-free due to the fact that no compressor is required. Peltier cooled incubators IPPeco / IPPecoplus can also be applied in entomology. No condensation in the interior chamber: due to the closed Peltier cooling system, no outside air is exchanged. Formation of condensation during the cooling process takes place on the outside heat sink. In addition, the fans integrated in the Peltier elements ensure a rapid transport of energy as well as an optimal temperature distribution. - LED light module for model sizes 110 to 750 (optional): dimmable LED light in 3 alternative colour temperatures (coldwhite or warmwhite light or cold-white plus warm-white light, dimmable in 10 % steps). - Acc. to DIN 12880:2007-05, EN 61010-1 (IEC 61010-1), 61010-2-010. AtmoCONTROL - control and logging software For direct setting parameters as well as process time. Fast and easy programming of complex processes via AtmoCONTROL by means of the mouse or touchpad on the notebook. - Reading out, managing and organising the data logger. - Saving the log memory in various formats. - Online monitoring of up to 32 connected appliances. - Optical alarms when the alarm limits individually set at the ControlCOCKPIT are exceeded. - Automatic alarm to one or several e-mail addresses. - SingleDISPLAY: ControlCOCKPIT with one TFT colour graphical display. - One temperature sensor Pt100 DIN class A in a 4-wire circuit. - AtmoCONTROL software for reading out, managing and organising the data logger via ethernet interface (temporary trial version can be downloaded). USB stick with AtmoCONTROL software available as accessory on demand. - Ethernet interface on the rear of the appliance for reading out the protocol log. - Double overtemperature protection: electronic temperature monitoring with freely adjustable monitoring temperature, mechanical temperature limiter TB acc. to DIN 12880. Heating and cooling seamlessly with one system thanks to Peltier technology. In this respect, cooled incubators IPPeco not only contribute to climate protection, but also achieve an additional decrease in operating costs of up 90 % compared to compressor technology. Outstanding control precision and extremely small fluctuations. Extremely quiet, space-saving and vibration-free due to the fact that no compressor is required. Peltier cooled incubators IPPeco / IPPecoplus can also be applied in entomology. No condensation in the interior chamber: due to the closed Peltier cooling system, no outside air is exchanged. Formation of condensation during the cooling process takes place on the outside heat sink. In addition, the fans integrated in the Peltier elements ensure a rapid transport of energy as well as an optimal temperature distribution. - LED light module for model sizes 110 to 750 (optional): dimmable LED light in 3 alternative colour temperatures (coldwhite or warmwhite light or cold-white plus warm-white light, dimmable in 10 % steps). - Acc. to DIN 12880:2007-05, EN 61010-1 (IEC 61010-1), 61010-2-010. AtmoCONTROL - control and logging software For direct setting parameters as well as process time. Fast and easy programming of complex processes via AtmoCONTROL by means of the mouse or touchpad on the notebook. - Reading out, managing and organising the data logger. - Saving the log memory in various formats. - Online monitoring of up to 32 connected appliances. - Optical alarms when the alarm limits individually set at the ControlCOCKPIT are exceeded. - Automatic alarm to one or several e-mail addresses. - SingleDISPLAY: ControlCOCKPIT with one TFT colour graphical display. - One temperature sensor Pt100 DIN class A in a 4-wire circuit. - AtmoCONTROL software for reading out, managing and organising the data logger via ethernet interface (temporary trial version can be downloaded). USB stick with AtmoCONTROL software available as accessory on demand. - Ethernet interface on the rear of the appliance for reading out the protocol log. - Double overtemperature protection: electronic temperature monitoring with freely adjustable monitoring temperature, mechanical temperature limiter TB acc. to DIN 12880.

Product Detail
New
IPP110eco, Omnilab

IPP110eco, Omnilab

Heating and cooling seamlessly with one system thanks to Peltier technology. In this respect, cooled incubators IPPeco not only contribute to climate protection, but also achieve an additional decrease in operating costs of up 90 % compared to compressor technology. Outstanding control precision and extremely small fluctuations. Extremely quiet, space-saving and vibration-free due to the fact that no compressor is required. Peltier cooled incubators IPPeco / IPPecoplus can also be applied in entomology. No condensation in the interior chamber: due to the closed Peltier cooling system, no outside air is exchanged. Formation of condensation during the cooling process takes place on the outside heat sink. In addition, the fans integrated in the Peltier elements ensure a rapid transport of energy as well as an optimal temperature distribution. - LED light module for model sizes 110 to 750 (optional): dimmable LED light in 3 alternative colour temperatures (coldwhite or warmwhite light or cold-white plus warm-white light, dimmable in 10 % steps). - Acc. to DIN 12880:2007-05, EN 61010-1 (IEC 61010-1), 61010-2-010. AtmoCONTROL - control and logging software For direct setting parameters as well as process time. Fast and easy programming of complex processes via AtmoCONTROL by means of the mouse or touchpad on the notebook. - Reading out, managing and organising the data logger. - Saving the log memory in various formats. - Online monitoring of up to 32 connected appliances. - Optical alarms when the alarm limits individually set at the ControlCOCKPIT are exceeded. - Automatic alarm to one or several e-mail addresses. - SingleDISPLAY: ControlCOCKPIT with one TFT colour graphical display. - One temperature sensor Pt100 DIN class A in a 4-wire circuit. - AtmoCONTROL software for reading out, managing and organising the data logger via ethernet interface (temporary trial version can be downloaded). USB stick with AtmoCONTROL software available as accessory on demand. - Ethernet interface on the rear of the appliance for reading out the protocol log. - Double overtemperature protection: electronic temperature monitoring with freely adjustable monitoring temperature, mechanical temperature limiter TB acc. to DIN 12880. Heating and cooling seamlessly with one system thanks to Peltier technology. In this respect, cooled incubators IPPeco not only contribute to climate protection, but also achieve an additional decrease in operating costs of up 90 % compared to compressor technology. Outstanding control precision and extremely small fluctuations. Extremely quiet, space-saving and vibration-free due to the fact that no compressor is required. Peltier cooled incubators IPPeco / IPPecoplus can also be applied in entomology. No condensation in the interior chamber: due to the closed Peltier cooling system, no outside air is exchanged. Formation of condensation during the cooling process takes place on the outside heat sink. In addition, the fans integrated in the Peltier elements ensure a rapid transport of energy as well as an optimal temperature distribution. - LED light module for model sizes 110 to 750 (optional): dimmable LED light in 3 alternative colour temperatures (coldwhite or warmwhite light or cold-white plus warm-white light, dimmable in 10 % steps). - Acc. to DIN 12880:2007-05, EN 61010-1 (IEC 61010-1), 61010-2-010. AtmoCONTROL - control and logging software For direct setting parameters as well as process time. Fast and easy programming of complex processes via AtmoCONTROL by means of the mouse or touchpad on the notebook. - Reading out, managing and organising the data logger. - Saving the log memory in various formats. - Online monitoring of up to 32 connected appliances. - Optical alarms when the alarm limits individually set at the ControlCOCKPIT are exceeded. - Automatic alarm to one or several e-mail addresses. - SingleDISPLAY: ControlCOCKPIT with one TFT colour graphical display. - One temperature sensor Pt100 DIN class A in a 4-wire circuit. - AtmoCONTROL software for reading out, managing and organising the data logger via ethernet interface (temporary trial version can be downloaded). USB stick with AtmoCONTROL software available as accessory on demand. - Ethernet interface on the rear of the appliance for reading out the protocol log. - Double overtemperature protection: electronic temperature monitoring with freely adjustable monitoring temperature, mechanical temperature limiter TB acc. to DIN 12880.

Product Detail
New
51031564, Omnilab

51031564, Omnilab

Energy efficient, precise temperature control, reliable temperature environment. A refrigerated incubator designed with your samples - and the environment - in mind. Experience up to 84 % energy savings when using Heratherm™ refrigerated incubators with Peltier technology compared to traditional compressor units. The Heratherm™ refrigerated incubators can help you reach an untapped potential in achieving temperature precision and efficiency, offering a complete package for your refrigerated incubation needs. With a temperature range of 5 to 70 °C, they are equipped with Peltier technology to reach the precise temperatures needed to perform your applications The incubators are ideal for applications where results demand precision, incl. the development process of new products, quality control in the food, beverage and cosmetics industries, water testing, cell culture and microbiological analysis or any applications with controlled temperature as a process step. Heratherm™ refrigerated incubators use Peltier modules which cool and heat thermoelectrically - requiring no refrigerants or other hazardous substances. The refrigerated incubators have an intelligent and automatic control of the Peltier module to ensure optimal adaptations based on set and actual temperatures. - Cooling and heating modes, as well as on / off cycles will be set to ensure precise temperature control. - The external fan speed will adapt automatically - fast running for cool down / heat up; slow running for keeping temperatures stable. - Advancement in incubation - products built for the precision and reliability you need. - Outstanding temperature uniformity and stability to keep the samples in a safe environment. - Low energy consumption. - CFC free / HFC free PU insulation foam for outstanding temperature performance and condensation prevention. - Heated door with intelligent energy control to ensure reduced condensation - even at low temperatures. - Sophisticated timer function with weekly / daily or real time mode. - Intuitive programmability function for defined temperature ramping, soak / cool and dwell. - Adjustable over-temperature shut-off for protocols that require setting of over temperature for protection - class 2 acc. to norm DIN12880. - Fan speed adapts automatically to achieve optimal temperature performance. - Intuitive features: easy-to-use microprocessor control, easy push-button calibration, large and clear vacuum fluorescent display for easy viewing. - Small footprint to use limited lab space efficiently. - Safe and user-friendly. - Safe viewing of samples through internal glass door with limited impact on temperature. - Safe containment with automatic over and under temperature alarm. - RS232 interface for data logging. - No power cut-out with fatal consequence for samples, but maintenance of selected temperature. - St. steel interior (1.4301/ASTM 304) and rounded corners for easy cleaning. Energy efficient, precise temperature control, reliable temperature environment. A refrigerated incubator designed with your samples - and the environment - in mind. Experience up to 84 % energy savings when using Heratherm™ refrigerated incubators with Peltier technology compared to traditional compressor units. The Heratherm™ refrigerated incubators can help you reach an untapped potential in achieving temperature precision and efficiency, offering a complete package for your refrigerated incubation needs. With a temperature range of 5 to 70 °C, they are equipped with Peltier technology to reach the precise temperatures needed to perform your applications The incubators are ideal for applications where results demand precision, incl. the development process of new products, quality control in the food, beverage and cosmetics industries, water testing, cell culture and microbiological analysis or any applications with controlled temperature as a process step. Heratherm™ refrigerated incubators use Peltier modules which cool and heat thermoelectrically - requiring no refrigerants or other hazardous substances. The refrigerated incubators have an intelligent and automatic control of the Peltier module to ensure optimal adaptations based on set and actual temperatures. - Cooling and heating modes, as well as on / off cycles will be set to ensure precise temperature control. - The external fan speed will adapt automatically - fast running for cool down / heat up; slow running for keeping temperatures stable. - Advancement in incubation - products built for the precision and reliability you need. - Outstanding temperature uniformity and stability to keep the samples in a safe environment. - Low energy consumption. - CFC free / HFC free PU insulation foam for outstanding temperature performance and condensation prevention. - Heated door with intelligent energy control to ensure reduced condensation - even at low temperatures. - Sophisticated timer function with weekly / daily or real time mode. - Intuitive programmability function for defined temperature ramping, soak / cool and dwell. - Adjustable over-temperature shut-off for protocols that require setting of over temperature for protection - class 2 acc. to norm DIN12880. - Fan speed adapts automatically to achieve optimal temperature performance. - Intuitive features: easy-to-use microprocessor control, easy push-button calibration, large and clear vacuum fluorescent display for easy viewing. - Small footprint to use limited lab space efficiently. - Safe and user-friendly. - Safe viewing of samples through internal glass door with limited impact on temperature. - Safe containment with automatic over and under temperature alarm. - RS232 interface for data logging. - No power cut-out with fatal consequence for samples, but maintenance of selected temperature. - St. steel interior (1.4301/ASTM 304) and rounded corners for easy cleaning.

Product Detail
New
MIR-254-PE, Omnilab

MIR-254-PE, Omnilab

Panasonic´s MIR cooled series incubators provide a temperature range of - 10 to 60 °C. Incorporating an 8-bit microcomputer, these incubators control the heater and compressor within a precise ± 0.2 °C and ± 1.5 °C range, respectively. - Programmable 3-step operation with microcomputer control: combining flexible temperature and time control, a maximum 3-step plus constant operation or max. 3-step repeating operation can be programmed according to the experimentation requirements. The one-step setting time ranges from 0.0 to 99.5 h in increments of 30 min. A program can be set to repeat for a minimum of once up to a maximum of 99 times. Ideal for experimentation during night time or holidays, experimentation that requires settings to be changed, and microorganism culture and preservation. Constant operation mode without step operation is also available. - Microprocessor control with feed forward function: SANYO cooled incubators incorporate a high precision microprocessor temperature control combined with a heater PID and compressor ON-OFF system. This system has a feed forward function that monitors the operating conditions of the compressor, ensuring accurate temperature control of the chamber. - Energy savings: because heater output and compressor on / off are microprocessor controlled, optimum automatic operation according to ambient temperature and fluctuation of chamber load is possible, resulting in high-energy savings. - Foamed-in-place rigid polyurethane insulation. - Triple-pane glass observation window plus programmable 15 W fluorescent lamp. - Automatic setting temperature alarm. - Independent over-temperature protection device. - Programmed memory backup mechanism: should the power source be interrupted due to power failure or other event, programmed data remains stored in memory for approx. 5 h. When the power source is restored, operation can be continued according to the predetermined program. - Automatic return buzzer switch. - Key lock switch. - Auto return mechanism: this mechanism automatically returns the chamber temperature indicator to its normal indication when the control key is not operated for approx. 90 s at each setting mode. - Trouble monitor (self diagnostic function): should a malfunction occur, the location of the malfunction can be indicated, allowing quick operator response. - Graphic display with data log function for 2 weeks, password protection programmable for up to 12 steps, 10 programs max. 99 cycles, real-time clock and sequence control. - Door rabbet changeable. Panasonic´s MIR cooled series incubators provide a temperature range of - 10 to 60 °C. Incorporating an 8-bit microcomputer, these incubators control the heater and compressor within a precise ± 0.2 °C and ± 1.5 °C range, respectively. - Programmable 3-step operation with microcomputer control: combining flexible temperature and time control, a maximum 3-step plus constant operation or max. 3-step repeating operation can be programmed according to the experimentation requirements. The one-step setting time ranges from 0.0 to 99.5 h in increments of 30 min. A program can be set to repeat for a minimum of once up to a maximum of 99 times. Ideal for experimentation during night time or holidays, experimentation that requires settings to be changed, and microorganism culture and preservation. Constant operation mode without step operation is also available. - Microprocessor control with feed forward function: SANYO cooled incubators incorporate a high precision microprocessor temperature control combined with a heater PID and compressor ON-OFF system. This system has a feed forward function that monitors the operating conditions of the compressor, ensuring accurate temperature control of the chamber. - Energy savings: because heater output and compressor on / off are microprocessor controlled, optimum automatic operation according to ambient temperature and fluctuation of chamber load is possible, resulting in high-energy savings. - Foamed-in-place rigid polyurethane insulation. - Triple-pane glass observation window plus programmable 15 W fluorescent lamp. - Automatic setting temperature alarm. - Independent over-temperature protection device. - Programmed memory backup mechanism: should the power source be interrupted due to power failure or other event, programmed data remains stored in memory for approx. 5 h. When the power source is restored, operation can be continued according to the predetermined program. - Automatic return buzzer switch. - Key lock switch. - Auto return mechanism: this mechanism automatically returns the chamber temperature indicator to its normal indication when the control key is not operated for approx. 90 s at each setting mode. - Trouble monitor (self diagnostic function): should a malfunction occur, the location of the malfunction can be indicated, allowing quick operator response. - Graphic display with data log function for 2 weeks, password protection programmable for up to 12 steps, 10 programs max. 99 cycles, real-time clock and sequence control. - Door rabbet changeable.

Product Detail
allied chemi
  • secure-payment
  • visa
  • american-express
  • master-card

© 2023 Copyright. All Rights Reserved. Unit 19, Euroway House, Roydsdale Way, Bradford, BD4 6SE, UK