Material: glass. Double counting grid. Counting grid with nine large squares. The smallest square in the centre is split into 16 group squares and these in turn are split into 16 small squares. Large square: 1 mm 2 Group square: 0.04 mm 2 Small square: 0.0025 mm 2 Counting chamber Neubauer Bright lines, 2 spring clamps The grid structure is incorporated in a very thin, transparent metal layer. The bright lines contrast well with the darker, metallic background, which simplifies the evaluation of cell suspensions.Spring clips securely fix the coverslip to the counting chamber. In vitro diagnostic medical device class A Delivery incl. two haemocytometer coverslips (20 x 26 mm).
Material: glass. For leucocyte and erythrocyte counting. Double counting grid. Counting grid with nine large squares for leucocyte counting. Each large square is divided into 16 group squares for erythrocyte counting. The group squares are not subdivided further. Large square: 1 mm 2 Group square: 0.04 mm 2 Counting chamber Bürker Dark lines The counting grid appears under the microscope as a grid of dark lines. In vitro diagnostic medical device class A Delivery incl. two haemocytometer coverslips (20 x 26 mm).
Material: glass. For leucocyte, thrombocyte and erythrocyte counting. Double counting grid. Counting grid with nine large squares. The four corner squares are used for leucocyte counting. The smallest square in the centre is split into 25 group squares and these in turn are split into 16 small squares. Five of the group squares are used for erythrocyte counting. Large square: 1 mm 2 Group square: 0.04 mm 2 Small square: 0.0025 mm 2 Counting chamber Neubauer improved Dark lines The counting grid appears under the microscope as a grid of dark lines. In vitro diagnostic medical device class A Delivery incl. two haemocytometer coverslips (20 x 26 mm).
Material: glass. For leucocyte, thrombocyte and erythrocyte counting. Double counting grid. Counting grid with nine large squares. The four corner squares are used for leucocyte counting. The smallest square in the centre is split into 25 group squares and these in turn are split into 16 small squares. Five of the group squares are used for erythrocyte counting. Large square: 1 mm 2 Group square: 0.04 mm 2 Small square: 0.0025 mm 2 Counting chamber Neubauer improved Bright lines The grid structure is incorporated in a very thin, transparent metal layer. The bright lines contrast well with the darker, metallic background, which simplifies the evaluation of cell suspensions. In vitro diagnostic medical device class A Delivery incl. two haemocytometer coverslips (20 x 26 mm).
Material: glass. Double counting grid. Counting grid with nine large squares. The smallest square in the centre is split into 16 group squares and these in turn are split into 16 small squares. Large square: 1 mm 2 Group square: 0.04 mm 2 Small square: 0.0025 mm 2 Counting chamber Neubauer Dark lines, 2 spring clamps The counting grid appears under the microscope as a grid of dark lines. Spring clips securely fix the coverslip to the counting chamber. In vitro diagnostic medical device class A Delivery incl. two haemocytometer coverslips (20 x 26 mm).
Material: glass. Double counting grid. Counting grid with nine large squares. The smallest square in the centre is split into 16 group squares and these in turn are split into 16 small squares. Large square: 1 mm 2 Group square: 0.04 mm 2 Small square: 0.0025 mm 2 Counting chamber Neubauer Dark lines The counting grid appears under the microscope as a grid of dark lines. In vitro diagnostic medical device class A Delivery incl. two haemocytometer coverslips (20 x 26 mm).
Material: glass. For leucocyte, thrombocyte and erythrocyte counting. Double counting grid. Counting grid with nine large squares. The four corner squares are used for leucocyte counting. The smallest square in the centre is split into 25 group squares and these in turn are split into 16 small squares. Five of the group squares are used for erythrocyte counting. Large square: 1 mm 2 Group square: 0.04 mm 2 Small square: 0.0025 mm 2 Counting chamber Neubauer improved Bright lines, 2 spring clamps The grid structure is incorporated in a very thin, transparent metal layer. The bright lines contrast well with the darker, metallic background, which simplifies the evaluation of cell suspensions.Spring clamps securely fix the coverslip to the counting chamber. In vitro diagnostic medical device class A Delivery incl. two haemocytometer coverslips (20 x 26 mm).
Material: glass. For counting cells in fluid. Double counting grid. Total area: 16 mm 2 , counting grid with 16 large squares. The total area is counted. Counting chamber Fuchs-Rosenthal Dark lines The counting grid appears under the microscope as a grid of dark lines. In vitro diagnostic medical device class A Delivery incl. two haemocytometer coverslips (24 x 24 mm).
Material: glass. For leucocyte, thrombocyte and erythrocyte counting. Double counting grid. Counting grid with nine large squares. The four corner squares are used for leucocyte counting. The smallest square in the centre is split into 25 group squares and these in turn are split into 16 small squares. Five of the group squares are used for erythrocyte counting. Large square: 1 mm 2 Group square: 0.04 mm 2 Small square: 0.0025 mm 2 Counting chamber Neubauer improved Dark lines The counting grid appears under the microscope as a grid of dark lines. In vitro diagnostic medical device class A Delivery incl. two haemocytometer coverslips (20 x 26 mm).
Material: glass. Double net ruling. For counting cells in liquor or for counting nematodes . The square base area of 100 mm 2 is divided into 40 rectangular areas each measuring 0.25 x 10 mm. Counting chamber Nageotte In vitro diagnostic medical device class A Delivery incl. two haemocytometer coverslips (30 x 30, thickness 0.4 mm).
Material: glass. For counting worm eggs. Suitable for solid media. With two fields and affixed coverslip with two counting grids measuring 10 x 10 mm (divided into 10 parts). The coverslip is affixed on three supports. Distance between base plate and coverslip: 1.5 mm. Counting chamber McMaster Not a medical device / Not an IVD product
Material: glass. Double net ruling. For counting cells in liquor or for counting nematodes. The counting grid covers an area of 2 mm x 2.5 mm. The large rectangles measure 0.25 x 0.20 mm = 0.05 mm 2 and are divided into 20 small squares each measuring 0.05 x 0.05 mm = 0.0025 mm 2 . Counting chamber Malassez The counting grid appears under the microscope as a grid of dark lines. In vitro diagnostic medical device class A Delivery incl. two haemocytometer coverslips (20 x 26 mm).