Deliver to United Kingdom
0
Products Found: 40
Showing Results For: PAGE ready-made Solutions

PAGE ready-made Solutions


A121.1, Carl Roth

MF Part: A121.1
MOQ: 1 - 5
£ 56.03
In Stock
more details

A515.1, Carl Roth

MF Part: A515.1
MOQ: 1 - 5
£ 98.73
In Stock
more details

T802.3, Carl Roth

MF Part: T802.3
MOQ: 1 - 5
£ 60.89
In Stock
more details

A121.3, Carl Roth

MF Part: A121.3
MOQ: 1 - 5
£ 29.52
In Stock
more details

3029.3, Carl Roth

MF Part: 3029.3
MOQ: 1 - 5
£ 30.87
In Stock
more details

3050.1, Carl Roth

MF Part: 3050.1
MOQ: 1 - 5
£ 30.87
In Stock
more details

A431.1, Carl Roth

MF Part: A431.1
MOQ: 1 - 5
£ 128.21
In Stock
more details

A515.4, Carl Roth

MF Part: A515.4
MOQ: 1 - 5
£ 42.48
In Stock
more details

T802.1, Carl Roth

MF Part: T802.1
MOQ: 1 - 5
£ 88.92
In Stock
more details

3043.3, Carl Roth

MF Part: 3043.3
MOQ: 1 - 5
£ 29.93
In Stock
more details

3043.2, Carl Roth

MF Part: 3043.2
MOQ: 1 - 5
£ 16.38
In Stock
more details

3043.1, Carl Roth

MF Part: 3043.1
MOQ: 1 - 5
£ 72.09
In Stock
more details

New Items
New
A121.1, Carl Roth

A121.1, Carl Roth

Ready-to-use, gas-stabilized ready-to-use acrylamide solutions with different concentrations and ratios of acrylamide to bisacrylamide. The ROTIPHORESE ® gel solutions are very easy to use and enable reproducible and high-resolution gel electrophoresis. Directions for use ROTIPHORESE ® gel solutions can be used for protein and nucleic acid separation in PAGE gels. The high-purity solutions can be combined with any buffer system. During sequencing, they facilitate the preparation of sequencing gels of consistent quality; our fluorescence-free gel solutions are recommended for the use of automatic sequencers. Please note The ROTIPHORESE ® acrylamide and bisacrylamide solutions from Carl ROTH are produced only from acrylic acid-free substances and are strictly controlled in acrylamide content and pH. Oxidation products are removed from the solution by a selective absorption process. Their new formation and the polymerization of the solution are prevented by stabilizing the solution with inert gas. In order to ensure a high lot-to-lot consistency of our ROTIPHORESE ® solutions, each batch is subjected to an electrophoretic test. Fluorescence-free gel solutions are tested for suitability for automatic sequencers. NF acrylamide solutions are very well suited for application in fluorescence-labelled automated sequencing, e.g. using LI-COR or ABI slab gel sequencers. ROTIPHORESE ® NF ready-to-use solutions for automated sequencing are special fluorescence-free acrylamide/bisacrylamide mixtures of highest quality as required for automatic sequencing. Made from 4x cristallised acrylamide. ROTIPHORESE ® NF-Acrylamide/Bis-solution 40 (29:1) ROTIPHORESE ® 40 %, ready-to-use, gas-stabilized, fluorescence-free Cross linking 3,3. ROTIPHORESE ® NF ready-to-use solutions are made from 4x crystallized acrylamide and are special fluorescence-free acrylamide/bisacrylamide mixtures of the highest quality, as required for automatic sequencing.

Product Detail
New
A515.1, Carl Roth

A515.1, Carl Roth

Ready-to-use, gas-stabilized ready-to-use acrylamide solutions with different concentrations and ratios of acrylamide to bisacrylamide. The ROTIPHORESE ® gel solutions are very easy to use and enable reproducible and high-resolution gel electrophoresis. Directions for use ROTIPHORESE ® gel solutions can be used for protein and nucleic acid separation in PAGE gels. The high-purity solutions can be combined with any buffer system. During sequencing, they facilitate the preparation of sequencing gels of consistent quality; our fluorescence-free gel solutions are recommended for the use of automatic sequencers. Please note The ROTIPHORESE ® acrylamide and bisacrylamide solutions from Carl ROTH are produced only from acrylic acid-free substances and are strictly controlled in acrylamide content and pH. Oxidation products are removed from the solution by a selective absorption process. Their new formation and the polymerization of the solution are prevented by stabilizing the solution with inert gas. In order to ensure a high lot-to-lot consistency of our ROTIPHORESE ® solutions, each batch is subjected to an electrophoretic test. Fluorescence-free gel solutions are tested for suitability for automatic sequencers. ROTIPHORESE ® Gel 40 (29:1) ROTIPHORESE ® 40 %, ready-to-use, gas-stabilized Cross linking 3,3.

Product Detail
New
T802.3, Carl Roth

T802.3, Carl Roth

Ready-to-use, gas-stabilized ready-to-use acrylamide solutions with different concentrations and ratios of acrylamide to bisacrylamide. The ROTIPHORESE ® gel solutions are very easy to use and enable reproducible and high-resolution gel electrophoresis. Directions for use ROTIPHORESE ® gel solutions can be used for protein and nucleic acid separation in PAGE gels. The high-purity solutions can be combined with any buffer system. During sequencing, they facilitate the preparation of sequencing gels of consistent quality; our fluorescence-free gel solutions are recommended for the use of automatic sequencers. Please note The ROTIPHORESE ® acrylamide and bisacrylamide solutions from Carl ROTH are produced only from acrylic acid-free substances and are strictly controlled in acrylamide content and pH. Oxidation products are removed from the solution by a selective absorption process. Their new formation and the polymerization of the solution are prevented by stabilizing the solution with inert gas. In order to ensure a high lot-to-lot consistency of our ROTIPHORESE ® solutions, each batch is subjected to an electrophoretic test. Fluorescence-free gel solutions are tested for suitability for automatic sequencers. ROTIPHORESE ® Gel 40 (37.5:1) ROTIPHORESE ® 40 %, ready-to-use, gas-stabilized Cross linking 2,7. Not a medical device / Not an IVD product

Product Detail
New
A121.3, Carl Roth

A121.3, Carl Roth

Ready-to-use, gas-stabilized ready-to-use acrylamide solutions with different concentrations and ratios of acrylamide to bisacrylamide. The ROTIPHORESE ® gel solutions are very easy to use and enable reproducible and high-resolution gel electrophoresis. Directions for use ROTIPHORESE ® gel solutions can be used for protein and nucleic acid separation in PAGE gels. The high-purity solutions can be combined with any buffer system. During sequencing, they facilitate the preparation of sequencing gels of consistent quality; our fluorescence-free gel solutions are recommended for the use of automatic sequencers. Please note The ROTIPHORESE ® acrylamide and bisacrylamide solutions from Carl ROTH are produced only from acrylic acid-free substances and are strictly controlled in acrylamide content and pH. Oxidation products are removed from the solution by a selective absorption process. Their new formation and the polymerization of the solution are prevented by stabilizing the solution with inert gas. In order to ensure a high lot-to-lot consistency of our ROTIPHORESE ® solutions, each batch is subjected to an electrophoretic test. Fluorescence-free gel solutions are tested for suitability for automatic sequencers. NF acrylamide solutions are very well suited for application in fluorescence-labelled automated sequencing, e.g. using LI-COR or ABI slab gel sequencers. ROTIPHORESE ® NF ready-to-use solutions for automated sequencing are special fluorescence-free acrylamide/bisacrylamide mixtures of highest quality as required for automatic sequencing. Made from 4x cristallised acrylamide. ROTIPHORESE ® NF-Acrylamide/Bis-solution 40 (29:1) ROTIPHORESE ® 40 %, ready-to-use, gas-stabilized, fluorescence-free Cross linking 3,3. ROTIPHORESE ® NF ready-to-use solutions are made from 4x crystallized acrylamide and are special fluorescence-free acrylamide/bisacrylamide mixtures of the highest quality, as required for automatic sequencing. Not a medical device / Not an IVD product

Product Detail
New
3029.3, Carl Roth

3029.3, Carl Roth

Ready-to-use, gas-stabilized ready-to-use acrylamide solutions with different concentrations and ratios of acrylamide to bisacrylamide. The ROTIPHORESE ® gel solutions are very easy to use and enable reproducible and high-resolution gel electrophoresis. Directions for use ROTIPHORESE ® gel solutions can be used for protein and nucleic acid separation in PAGE gels. The high-purity solutions can be combined with any buffer system. During sequencing, they facilitate the preparation of sequencing gels of consistent quality; our fluorescence-free gel solutions are recommended for the use of automatic sequencers. Please note The ROTIPHORESE ® acrylamide and bisacrylamide solutions from Carl ROTH are produced only from acrylic acid-free substances and are strictly controlled in acrylamide content and pH. Oxidation products are removed from the solution by a selective absorption process. Their new formation and the polymerization of the solution are prevented by stabilizing the solution with inert gas. In order to ensure a high lot-to-lot consistency of our ROTIPHORESE ® solutions, each batch is subjected to an electrophoretic test. Fluorescence-free gel solutions are tested for suitability for automatic sequencers. ROTIPHORESE ® Gel 30 (37.5:1) ROTIPHORESE ® 30 %, ready-to-use, gas-stabilized Cross linking 2,7.

Product Detail
New
3050.1, Carl Roth

3050.1, Carl Roth

For preparation of 4-20 % sequencing gels Most simple handling of three optimised ready-to-use solutions No tedious dissolving of urea Prevents acrylamide dusts Reproducible, superior quality of gels In tried-and-tested ROTIPHORESE ® quality Convenient set containing three ready-made solutions for easy and fast casting of sequencing gels. Solutions are produced in ROTIPHORESE ® quality and are perfectly matched - providing superior, reproducible quality and high sequence resolution. In addition, the ROTIPHORESE ® Sequencing system allows flexible adaptation to the desired gel variant, so that the amount of urea can be varied in addition to the acrylamide concentration. By using the ROTIPHORESE ® Sequencing gel buffer concentrate and ROTIPHORESE ® Sequencing gel diluent contained in the set, gels with 50 % urea content are obtained. By adding defined quantities of ROTIPHORESE ® 10x TBE buffer or water, the urea content can be reduced to up to 40 %. Directions for use Handling is most simple: Measure and mix certain amounts of all three components, add APS and TEMED, and cast the gel. We recommend using the Carl ROTH sequencing electrophoresis chamber (Art. no. AE28). ROTIPHORESE ® Sequencing gel buffer concentrate ROTIPHORESE ® 50 % (w/v, 8,3 M) in 10x TBE Ready-to-use 10x TBE stock solution (1 M Tris borate, 20 mM EDTA buffer, pH 8,3) with 50 % urea . For the preparation of polyacrylamide sequencing gels with 40-50 % urea (6,7-8,3 M). Also part of the ROTIPHORESE ® DNA sequencing system (Art. No. A431.1).

Product Detail
New
A431.1, Carl Roth

A431.1, Carl Roth

For preparation of 4-20 % sequencing gels Most simple handling of three optimised ready-to-use solutions No tedious dissolving of urea Prevents acrylamide dusts Reproducible, superior quality of gels In tried-and-tested ROTIPHORESE ® quality Convenient set containing three ready-made solutions for easy and fast casting of sequencing gels. Solutions are produced in ROTIPHORESE ® quality and are perfectly matched - providing superior, reproducible quality and high sequence resolution. In addition, the ROTIPHORESE ® Sequencing system allows flexible adaptation to the desired gel variant, so that the amount of urea can be varied in addition to the acrylamide concentration. By using the ROTIPHORESE ® Sequencing gel buffer concentrate and ROTIPHORESE ® Sequencing gel diluent contained in the set, gels with 50 % urea content are obtained. By adding defined quantities of ROTIPHORESE ® 10x TBE buffer or water, the urea content can be reduced to up to 40 %. Directions for use Handling is most simple: Measure and mix certain amounts of all three components, add APS and TEMED, and cast the gel. We recommend using the Carl ROTH sequencing electrophoresis chamber (Art. no. AE28). ROTIPHORESE ® DNA sequencing system ROTIPHORESE ® for DNA sequencing The kit contains: 1 l ROTIPHORESE ® sequencing gel concentrate (Art. No. 3043.1) - ready-to-use, stabilised solution of 25 % acrylamide/bisacrylamide 19:1 with 50 % urea (8,3 M). 1 l ROTIPHORESE ® sequencing gel diluent (Art. No. 3047.1) - 50 % (g/v; 8,3 M) solution of urea in water. 250 ml ROTIPHORESE ® sequencing gel buffer concentrate (Art. No. 3050.1) - 10x TBE with 50 % urea (8,3 M). Detailed instructions for use are enclosed with the product.

Product Detail
New
A515.4, Carl Roth

A515.4, Carl Roth

Ready-to-use, gas-stabilized ready-to-use acrylamide solutions with different concentrations and ratios of acrylamide to bisacrylamide. The ROTIPHORESE ® gel solutions are very easy to use and enable reproducible and high-resolution gel electrophoresis. Directions for use ROTIPHORESE ® gel solutions can be used for protein and nucleic acid separation in PAGE gels. The high-purity solutions can be combined with any buffer system. During sequencing, they facilitate the preparation of sequencing gels of consistent quality; our fluorescence-free gel solutions are recommended for the use of automatic sequencers. Please note The ROTIPHORESE ® acrylamide and bisacrylamide solutions from Carl ROTH are produced only from acrylic acid-free substances and are strictly controlled in acrylamide content and pH. Oxidation products are removed from the solution by a selective absorption process. Their new formation and the polymerization of the solution are prevented by stabilizing the solution with inert gas. In order to ensure a high lot-to-lot consistency of our ROTIPHORESE ® solutions, each batch is subjected to an electrophoretic test. Fluorescence-free gel solutions are tested for suitability for automatic sequencers. ROTIPHORESE ® Gel 40 (29:1) ROTIPHORESE ® 40 %, ready-to-use, gas-stabilized Cross linking 3,3. Not a medical device / Not an IVD product

Product Detail
New
T802.1, Carl Roth

T802.1, Carl Roth

Ready-to-use, gas-stabilized ready-to-use acrylamide solutions with different concentrations and ratios of acrylamide to bisacrylamide. The ROTIPHORESE ® gel solutions are very easy to use and enable reproducible and high-resolution gel electrophoresis. Directions for use ROTIPHORESE ® gel solutions can be used for protein and nucleic acid separation in PAGE gels. The high-purity solutions can be combined with any buffer system. During sequencing, they facilitate the preparation of sequencing gels of consistent quality; our fluorescence-free gel solutions are recommended for the use of automatic sequencers. Please note The ROTIPHORESE ® acrylamide and bisacrylamide solutions from Carl ROTH are produced only from acrylic acid-free substances and are strictly controlled in acrylamide content and pH. Oxidation products are removed from the solution by a selective absorption process. Their new formation and the polymerization of the solution are prevented by stabilizing the solution with inert gas. In order to ensure a high lot-to-lot consistency of our ROTIPHORESE ® solutions, each batch is subjected to an electrophoretic test. Fluorescence-free gel solutions are tested for suitability for automatic sequencers. ROTIPHORESE ® Gel 40 (37.5:1) ROTIPHORESE ® 40 %, ready-to-use, gas-stabilized Cross linking 2,7.

Product Detail
New
3043.3, Carl Roth

3043.3, Carl Roth

For preparation of 4-20 % sequencing gels Most simple handling of three optimised ready-to-use solutions No tedious dissolving of urea Prevents acrylamide dusts Reproducible, superior quality of gels In tried-and-tested ROTIPHORESE ® quality Convenient set containing three ready-made solutions for easy and fast casting of sequencing gels. Solutions are produced in ROTIPHORESE ® quality and are perfectly matched - providing superior, reproducible quality and high sequence resolution. In addition, the ROTIPHORESE ® Sequencing system allows flexible adaptation to the desired gel variant, so that the amount of urea can be varied in addition to the acrylamide concentration. By using the ROTIPHORESE ® Sequencing gel buffer concentrate and ROTIPHORESE ® Sequencing gel diluent contained in the set, gels with 50 % urea content are obtained. By adding defined quantities of ROTIPHORESE ® 10x TBE buffer or water, the urea content can be reduced to up to 40 %. Directions for use Handling is most simple: Measure and mix certain amounts of all three components, add APS and TEMED, and cast the gel. We recommend using the Carl ROTH sequencing electrophoresis chamber (Art. no. AE28). ROTIPHORESE ® Sequencing gel concentrate ROTIPHORESE ® 25 % solution (19:1), ready-to-use, gas-stabilized Ready-to-use, stabilised solution of 25 % acrylamide/bisacrylamide 19:1. For the preparation of polyacrylamide sequencing gels containing 0-20 % monomer; 23,75 % acrylamide,1,25 % methylene bisacrylamide and 40-50 % urea (6,7-8,3 M). Cross linking 5. Also part of the ROTIPHORESE ® DNA sequencing system (Art. No. A431.1). Not a medical device / Not an IVD product

Product Detail
New
3043.2, Carl Roth

3043.2, Carl Roth

For preparation of 4-20 % sequencing gels Most simple handling of three optimised ready-to-use solutions No tedious dissolving of urea Prevents acrylamide dusts Reproducible, superior quality of gels In tried-and-tested ROTIPHORESE ® quality Convenient set containing three ready-made solutions for easy and fast casting of sequencing gels. Solutions are produced in ROTIPHORESE ® quality and are perfectly matched - providing superior, reproducible quality and high sequence resolution. In addition, the ROTIPHORESE ® Sequencing system allows flexible adaptation to the desired gel variant, so that the amount of urea can be varied in addition to the acrylamide concentration. By using the ROTIPHORESE ® Sequencing gel buffer concentrate and ROTIPHORESE ® Sequencing gel diluent contained in the set, gels with 50 % urea content are obtained. By adding defined quantities of ROTIPHORESE ® 10x TBE buffer or water, the urea content can be reduced to up to 40 %. Directions for use Handling is most simple: Measure and mix certain amounts of all three components, add APS and TEMED, and cast the gel. We recommend using the Carl ROTH sequencing electrophoresis chamber (Art. no. AE28). ROTIPHORESE ® Sequencing gel concentrate ROTIPHORESE ® 25 % solution (19:1), ready-to-use, gas-stabilized Ready-to-use, stabilised solution of 25 % acrylamide/bisacrylamide 19:1. For the preparation of polyacrylamide sequencing gels containing 0-20 % monomer; 23,75 % acrylamide,1,25 % methylene bisacrylamide and 40-50 % urea (6,7-8,3 M). Cross linking 5. Also part of the ROTIPHORESE ® DNA sequencing system (Art. No. A431.1).

Product Detail
New
3043.1, Carl Roth

3043.1, Carl Roth

For preparation of 4-20 % sequencing gels Most simple handling of three optimised ready-to-use solutions No tedious dissolving of urea Prevents acrylamide dusts Reproducible, superior quality of gels In tried-and-tested ROTIPHORESE ® quality Convenient set containing three ready-made solutions for easy and fast casting of sequencing gels. Solutions are produced in ROTIPHORESE ® quality and are perfectly matched - providing superior, reproducible quality and high sequence resolution. In addition, the ROTIPHORESE ® Sequencing system allows flexible adaptation to the desired gel variant, so that the amount of urea can be varied in addition to the acrylamide concentration. By using the ROTIPHORESE ® Sequencing gel buffer concentrate and ROTIPHORESE ® Sequencing gel diluent contained in the set, gels with 50 % urea content are obtained. By adding defined quantities of ROTIPHORESE ® 10x TBE buffer or water, the urea content can be reduced to up to 40 %. Directions for use Handling is most simple: Measure and mix certain amounts of all three components, add APS and TEMED, and cast the gel. We recommend using the Carl ROTH sequencing electrophoresis chamber (Art. no. AE28). ROTIPHORESE ® Sequencing gel concentrate ROTIPHORESE ® 25 % solution (19:1), ready-to-use, gas-stabilized Ready-to-use, stabilised solution of 25 % acrylamide/bisacrylamide 19:1. For the preparation of polyacrylamide sequencing gels containing 0-20 % monomer; 23,75 % acrylamide,1,25 % methylene bisacrylamide and 40-50 % urea (6,7-8,3 M). Cross linking 5. Also part of the ROTIPHORESE ® DNA sequencing system (Art. No. A431.1).

Product Detail
allied chemi
  • secure-payment
  • visa
  • american-express
  • master-card

© 2023 Copyright. All Rights Reserved. Unit 19, Euroway House, Roydsdale Way, Bradford, BD4 6SE, UK