HPLC column NUCLEODUR ® Sphinx RP, 3 µm, 250 mm, 2 mm
Order number: 355P.1
Part number: AC100006821
£ 904.64*
*Prices plus VAT plus shipping costs£ 1085.57*
*incl. VAT, plus shipping costsPrice Breakdown
1
6
24
Prepared to meet the demands of technical research tasks, this HPLC column, specifically the Nucleodur Sphinx RP, offers a unique combination of properties that make it an ideal choice for various applications. With its bifunctional RP phase featuring a balanced ratio of propylphenyl and C 18 ligands, this column showcases a distinct selectivity, broadening the possibilities for method development through both hydrophobic interactions and additional π-π interactions. The column's particle size of 3 μm ensures efficient separations while maintaining high resolution. Furthermore, the column's temperature stability up to 60°C and pressure stability of 600 bar cater to demanding experimental conditions. This analytical separation column, designed for use with acetonitrile-water eluents, is suitable for a wide range of applications including quinolone antibiotics, substituted aromatics,
- Category: Separation columns for HPLC
- Specific surface according to BET: 340 m²/g
- Interactions / retention mechanism: π-π and hydrophobic
- Particle size: 3 µm
- Phase: Sphinx RP
- Temperature stability: 60 ° C
- pH stability: 1,0-10,0
- Column volume: 0.8 ml
- Particle type: Fully porous particles (FPP)
- Recommended application(s): Quinolone antibiotics Suitable for LC-MS Substituted aromatics Sulfonamides Xanthines Additional π-π interactions
- Separation principle: Reversed phase (RP)
- Column type: HPLC column
- Surface chemistry: Bifunctional RP phase, balanced ratio of propylphenyl and C 18 ligands
- Pressure stability: 600 bar
- Column shape: Analytical separation column
- Pore volume: 0.9 ml/g
- USP listing: L1 L11
- Eluent in column: Acetonitrile - Water
- Endcapped: yes
- Pore size: 110 Å
- L x Ø internal (column): 250 x 2 mm
| Name | Value | |
|---|---|---|
| Phase | : | Sphinx RP |
| Endcapped | : | yes |
| Pore size | : | 110 Å |
| Column type | : | HPLC column |
| Pore volume | : | 0.9 ml/g |
| USP listing | : | L1 L11 |
| Column shape | : | Analytical separation column |
| pH stability | : | 1,0-10,0 |
| Column volume | : | 0.8 ml |
| Particle size | : | 3 µm |
| Particle type | : | Fully porous particles (FPP) |
| Eluent in column | : | Acetonitrile - Water |
| Surface chemistry | : | Bifunctional RP phase, balanced ratio of propylphenyl and C 18 ligands |
| Pressure stability | : | 600 bar |
| Separation principle | : | Reversed phase (RP) |
| Temperature stability | : | 60 ° C |
| L x Ø internal (column) | : | 250 x 2 mm |
| Recommended application(s) | : | Quinolone antibiotics Suitable for LC-MS Substituted aromatics Sulfonamides Xanthines Additional π-π interactions |
| Specific surface according to BET | : | 340 m²/g |
| Interactions / retention mechanism | : | π-π and hydrophobic |