HPLC column NUCLEODUR ® PolarTec, 3 µm, 125 mm, 2 mm
Order number: 34HC.1
Part number: AC100008506
£ 778.86*
*Prices plus VAT plus shipping costs£ 934.63*
*incl. VAT, plus shipping costsPrice Breakdown
1
6
24
Crafted to support technical production environments, the HPLC Column Nucleodur ® Polartec, 3 μm, 125 mm, 2 mm, falls under the category of Separation columns for HPLC. This analytical separation column features fully porous particles (FPP), a particle size of 3 μm, and a pore size of 110 Å, ensuring optimal performance. With a specific surface area of 340 m²/g according to BET, it offers a large active surface for efficient separations. The column's surface chemistry consists of an octadecyl phase (C 18 , ODS) modification, with an embedded polar group (PEG), providing both hydrophobic and polar (H bond) interactions for a wide range of applications, including amino acids, basic pharmaceuticals, nitrogen containing compounds, organic acids,
- Category: Separation columns for HPLC
- Interactions / retention mechanism: hydrophobic and polar (H bonds)
- Pressure stability: 600 bar
- Pore volume: 0.9 ml/g
- Column shape: Analytical separation column
- Particle size: 3 µm
- Eluent in column: Acetonitrile - Water
- Particle type: Fully porous particles (FPP)
- Surface chemistry: Octadecyl phase (C 18 , ODS) modification, with embedded polar group (PEG)
- Phase: PolarTec
- Specific surface according to BET: 340 m²/g
- pH stability: 1,0-9,0
- Endcapped: yes
- L x Ø internal (column): 125 x 2 mm
- Column volume: 0.37 ml
- Separation principle: Reversed phase (RP)
- USP listing: L1 L60
- Pore size: 110 Å
- Recommended application(s): Amino acids Basic pharmaceuticals Especially for polar compounds Nitrogen containing compounds Organic acids Pesticides Phenols Suitable for 100 % aqueous eluents Suitable for LC-MS Water-soluble vitamins
- Column type: HPLC column
- Temperature stability: 60 ° C
| Name | Value | |
|---|---|---|
| Phase | : | PolarTec |
| Endcapped | : | yes |
| Pore size | : | 110 Å |
| Column type | : | HPLC column |
| Pore volume | : | 0.9 ml/g |
| USP listing | : | L1 L60 |
| Column shape | : | Analytical separation column |
| pH stability | : | 1,0-9,0 |
| Column volume | : | 0.37 ml |
| Particle size | : | 3 µm |
| Particle type | : | Fully porous particles (FPP) |
| Eluent in column | : | Acetonitrile - Water |
| Surface chemistry | : | Octadecyl phase (C 18 , ODS) modification, with embedded polar group (PEG) |
| Pressure stability | : | 600 bar |
| Separation principle | : | Reversed phase (RP) |
| Temperature stability | : | 60 ° C |
| L x Ø internal (column) | : | 125 x 2 mm |
| Recommended application(s) | : | Amino acids Basic pharmaceuticals Especially for polar compounds Nitrogen containing compounds Organic acids Pesticides Phenols Suitable for 100 % aqueous eluents Suitable for LC-MS Water-soluble vitamins |
| Specific surface according to BET | : | 340 m²/g |
| Interactions / retention mechanism | : | hydrophobic and polar (H bonds) |