Processed under controlled conditions to ensure purity and stability, this Data Logger, Temperature and Humidity Log220, falls within the category of Temperature- & Humidity-Loggers. It features a temperature measurement range of -40 to 70 degrees Celsius internally, and an external range of -150 to 1370 degrees Celsius (when using specific models). Additionally, it can measure relative humidity levels between 0 and 100 percent. This device operates on a 3.6V 1/2 AA battery and has a measuring interval that can be set anywhere from 10 seconds to 24 hours. It also includes a differential pressure measurement capability. With a capacity to store up to 60,000 values, this logger is suitable for temperature documentation during transport and storage, as well as for monitoring measured values without expensive installation.
- Category: Temperature- & Humidity-Loggers
- Type: keine Angabe
- Humidity measurement: yes
- Min. measuring range [%mas]: 0
- Dimensions: 91.5 x 42 x 20 mm
- Min. rel. humidity [%]: 0
- Max. measuring range [hPA]: 1100
- Measuring interval: 10 s to 24 h
- Max. measuring temperature, external [°C]: 0
- Max. measuring range [lx]: 0
- Temperature measurement: yes
- Min. measuring temperature, internal [°C]: -40
- Height [mm]: 0
- CO2: 0 to 5000 pm (LOG220 E)
- Max. measuring range [ppm]: 0
- Atmospheric pressure: 300 to 1100 hPa (LOG220, LOG220 E)
- Min. measuring range [ppm]: 0
- Light measurement: no
- Temperature, internal: - 40 to + 70 °C
- Humidity: 0 to 100 % rF (LOG210, LOG220, LOG210 TC, LOG220 E)
- Length [mm]: 0
- Weight: 200 g
- Max. measuring range [%mas]: 0
- Max. measuring temperature, internal [°C]: 70
- Mains supply: 1 x 3.6 V 1/2 AA battery
- Min. measuring range [lx]: 0
- No. of storable values: 60000
- Differential pressure measurement: yes
- Gewichtg: keine Angabe
- Depth [mm]: 0
- Min. measuring temperature, external [°C]: 0
- Description: keine Angabe
- Protection class: keine Angabe
- Max. rel. humidity [%]: 100
- Min. measuring range [hPA]: 300
- CO2 measurement: no
- Temperature, external: - 150 to + 1370 °C (LOG200 TC, LOG210 TC)
| Name | Value | |
|---|---|---|
| CO2 | : | 0 to 5000 pm (LOG220 E) |
| Type | : | keine Angabe |
| Weight | : | 200 g |
| Gewichtg | : | keine Angabe |
| Humidity | : | 0 to 100 % rF (LOG210, LOG220, LOG210 TC, LOG220 E) |
| Dimensions | : | 91.5 x 42 x 20 mm |
| Description | : | keine Angabe |
| Mains supply | : | 1 x 3.6 V 1/2 AA battery |
| CO2 measurement | : | no |
| Protection class | : | keine Angabe |
| Light measurement | : | no |
| Measuring interval | : | 10 s to 24 h |
| Atmospheric pressure | : | 300 to 1100 hPa (LOG220, LOG220 E) |
| Humidity measurement | : | yes |
| Temperature, external | : | - 150 to + 1370 °C (LOG200 TC, LOG210 TC) |
| Temperature, internal | : | - 40 to + 70 °C |
| Max. rel. humidity [%] | : | 100 |
| No. of storable values | : | 60000 |
| Temperature measurement | : | yes |
| Max. measuring range [hPA] | : | 1100 |
| Min. measuring range [hPA] | : | 300 |
| Differential pressure measurement | : | yes |
| Max. measuring temperature, internal [°C] | : | 70 |
| Min. measuring temperature, internal [°C] | : | -40 |