Material: CE. Very high purity , contain no trace elements, heavy metals, sulphides or glycerine Low reactivity of the membrane, therefore hardly any adsorption of proteins and liposomes No time-consuming cleaning processes necessary Max. application temperature +37 °C Packaged moist in 0.05% sodium azide solution Recommended storage temperature +4 °C Dialysis membrane Spectra/Por ® Biotech CE MWCO 8000-10,000 Not a medical device / Not an IVD product
Material: cellulose, regenerated. Packaged moist in 0.05% sodium azide solution, on rolls Highly pure membranes without trace elements such as heavy metals, sulphides, glycerine Can be used without the need for complex cleaning processes Recommended storage temperature +4 °C Max. application temperature +60 °C Dialysis membrane Spectra/Por ® 7 MWCO 8000 Not a medical device / Not an IVD product
Material: cellulose, regenerated. Hose membrane pieces on rolls, packaged dry . Particularly suitable for small-scale dialysis and for testing membranes for special applications. Trial kit Spectra/Por ® 1-3 Spectra/Por ® 1 - MWCO 6000-8000 Not a medical device / Not an IVD product Delivery incl. 1 pair of Spectra/Por ® locking clips made of PP (1x with weight, 1x without).
Material: cellulose, regenerated. Packaged moist in 0.05% sodium azide solution, on rolls Highly pure membranes without trace elements such as heavy metals, sulphides, glycerine Can be used without the need for complex cleaning processes Recommended storage temperature +4 °C Max. application temperature +60 °C Dialysis membrane Spectra/Por ® 7 MWCO 2000 Not a medical device / Not an IVD product
Material: CE. Hose membrane pieces on rolls, packaged moist in 0.05% sodium azide solution. Particularly suitable for dialysis where only a small amount of tubing is required (test runs, small-scale applications, etc.). Trial kit Spectra/Por ® Biotech CE Not a medical device / Not an IVD product Delivery incl. 1 pair of Spectra/Por ® universal locking clips (red, seal length 50 mm).
Material: CE. Very high purity , contain no trace elements, heavy metals, sulphides or glycerine Low reactivity of the membrane, therefore hardly any adsorption of proteins and liposomes No time-consuming cleaning processes necessary Max. application temperature +37 °C Packaged moist in 0.05% sodium azide solution Recommended storage temperature +4 °C Dialysis membrane Spectra/Por ® Biotech CE MWCO 50,000 Not a medical device / Not an IVD product
Material: cellulose, regenerated. Packaged moist in 0.05% sodium azide solution, on rolls Contain low quantities of contaminations such as sulphides and heavy metals Recommended storage temperature +4 °C Max. application temperature +60 °C Metal traces: cadmium <0.02 ppm, lead 2-6 ppm, chromium 0.1-0.2 ppm, magnesium 0.1-0.3 ppm, copper 0.8-1.2 ppm, nickel 1.3-1.7 ppm, iron 20-60 ppm, zinc 1.5-5 ppm Dialysis membrane Spectra/Por ® 6 MWCO 25,000 (opaque) Not a medical device / Not an IVD product
Material: cellulose, regenerated. Packaged moist in 0.05% sodium azide solution, on rolls Contain low quantities of contaminations such as sulphides and heavy metals Recommended storage temperature +4 °C Max. application temperature +60 °C Metal traces: cadmium <0.02 ppm, lead 2-6 ppm, chromium 0.1-0.2 ppm, magnesium 0.1-0.3 ppm, copper 0.8-1.2 ppm, nickel 1.3-1.7 ppm, iron 20-60 ppm, zinc 1.5-5 ppm Dialysis membrane Spectra/Por ® 6 MWCO 2000 Not a medical device / Not an IVD product
Material: cellulose, regenerated. Autoclavable: yes. Colourless, transparent to slightly opaque, semi-permeable and seamless. Application area: dialysis and ultrafiltration in the laboratory. Exclusion limit (MWCO) 14,000 Dry packaged on rolls, treated with glycerine Stable in the pH range from 5 to 9 No unspecific protein binding, protein adsorption <1 ng/g Autoclavable up to +120 °C (max. 15 min, immersed in distilled water) Dialysis membrane Membra-Cel™ Not a medical device / Not an IVD product
Material: cellulose, regenerated. Packaged moist in 0.05% sodium azide solution, on rolls Highly pure membranes without trace elements such as heavy metals, sulphides, glycerine Can be used without the need for complex cleaning processes Recommended storage temperature +4 °C Max. application temperature +60 °C Dialysis membrane Spectra/Por ® 7 MWCO 2000 Not a medical device / Not an IVD product
Material: cellulose, regenerated. Suitable for laboratory experiments. MWCO approx. 10,000-20,000 daltons. Packaged dry on roles, glycerine content approx. 21%. Dialysis membrane Nalo Not a medical device / Not an IVD product
Material: cellulose, regenerated. High-quality membranes on rolls, packaged dry Max. application temperature +60 °C Good resistance to chemicals Treated with glycerine to protect against embrittlement Contain low quantities of contaminations such as sulphides and heavy metals Metal traces: cadmium <0.02 ppm, lead 2-6 ppm, chromium 0.1-0.2 ppm, magnesium 0.1-0.3 ppm, copper 0.8-1.2 ppm, nickel 1.3-1.7 ppm, iron 20-60 ppm, zinc 1.5-5 ppm Dialysis membrane Spectra/Por ® 1-4 Spectra/Por ® 4 - MWCO 12,000-14,000 Not a medical device / Not an IVD product