Deliver to United Kingdom
0
Products Found: 32
Showing Results For: Microlitre syringes

Microlitre syringes



New Items
New
E120.1, Roth

E120.1, Roth

Material: borosilicate glass, stainless steel 1.4301. Needle with chamfered tip, fixed in place. This syringe may not be used for fluoric or strongly acidic liquids. Technical specifications: tested up to 3.0 bar liquid pressure; calibrated with a ±1% accuracy; precise and easy-to-read scale; exact finishing prevents the creation of air bubbles, as far as possible. Microlitre syringe standard Not a medical device / Not an IVD product

Product Detail
New
E111.1, Roth

E111.1, Roth

Material: borosilicate glass, stainless steel 1.4301. No longer possible to bend. Super-elastic plungers made from Ni-Ti alloy. Plungers always return to their original shape. Needle fixed in place. Technical specifications: tested up to 3.0 bar liquid pressure; calibrated with a ±1% accuracy; precise and easy-to-read scale; exact finishing prevents the creation of air bubbles, as far as possible. Microlitre syringe with super-elastic plunger Not a medical device / Not an IVD product

Product Detail
New
E134.1, Roth

E134.1, Roth

Material: borosilicate glass, PTFE, stainless steel 1.4301. With specially polished syringe hole and PTFE plunger tip. Gas and liquid-tight up to a pressure of 5.0 kg/cm 2 . Technical specifications: tested up to 3.0 bar liquid pressure; calibrated with a ±1% accuracy; precise and easy-to-read scale; exact finishing prevents the creation of air bubbles, as far as possible. Syringe gas-tight with Luer-Lock connection Ideal for applications requiring particular inertness. Not a medical device / Not an IVD product Delivery without needle.

Product Detail
New
E128.1, Roth

E128.1, Roth

Material: borosilicate glass, PTFE, stainless steel 1.4301. With specially polished syringe hole and PTFE plunger tip. Gas and liquid-tight up to a pressure of 5.0 kg/cm 2 . Technical specifications: tested up to 3.0 bar liquid pressure; calibrated with a ±1% accuracy; precise and easy-to-read scale; exact finishing prevents the creation of air bubbles, as far as possible. Syringe gas-tight with screw-top connection Needle with chamfered tip, replaceable. Not a medical device / Not an IVD product Delivery incl. needle.

Product Detail
New
E114.1, Roth

E114.1, Roth

Material: borosilicate glass, stainless steel 1.4301. Needle with chamfered tip, fixed in place. This syringe may not be used for fluoric or strongly acidic liquids. Technical specifications: tested up to 3.0 bar liquid pressure; calibrated with a ±1% accuracy; precise and easy-to-read scale; exact finishing prevents the creation of air bubbles, as far as possible. Microlitre syringe standard Not a medical device / Not an IVD product

Product Detail
New
E116.1, Roth

E116.1, Roth

Material: borosilicate glass, stainless steel 1.4301. Needle with chamfered tip, fixed in place. This syringe may not be used for fluoric or strongly acidic liquids. Technical specifications: tested up to 3.0 bar liquid pressure; calibrated with a ±1% accuracy; precise and easy-to-read scale; exact finishing prevents the creation of air bubbles, as far as possible. Microlitre syringe standard Not a medical device / Not an IVD product

Product Detail
New
E124.1, Roth

E124.1, Roth

Material: borosilicate glass, stainless steel 1.4301. For Rheodyne valves. The specially polished, blunt needle tip ensures the perfect density and prevents damage to the seal and rotor. Needle fixed in place. Technical specifications: tested up to 3.0 bar liquid pressure; calibrated with a ±1% accuracy; precise and easy-to-read scale; exact finishing prevents the creation of air bubbles, as far as possible. Microlitre syringe for HPLC Not a medical device / Not an IVD product

Product Detail
New
E115.1, Roth

E115.1, Roth

Material: borosilicate glass, stainless steel 1.4301. Needle with chamfered tip, fixed in place. This syringe may not be used for fluoric or strongly acidic liquids. Technical specifications: tested up to 3.0 bar liquid pressure; calibrated with a ±1% accuracy; precise and easy-to-read scale; exact finishing prevents the creation of air bubbles, as far as possible. Microlitre syringe standard Not a medical device / Not an IVD product

Product Detail
New
E130.1, Roth

E130.1, Roth

Material: borosilicate glass, PTFE, stainless steel 1.4301. With specially polished syringe hole and PTFE plunger tip. Gas and liquid-tight up to a pressure of 5.0 kg/cm 2 . Technical specifications: tested up to 3.0 bar liquid pressure; calibrated with a ±1% accuracy; precise and easy-to-read scale; exact finishing prevents the creation of air bubbles, as far as possible. Syringe gas-tight with screw-top connection Needle with chamfered tip, replaceable. Not a medical device / Not an IVD product Delivery incl. needle.

Product Detail
New
E135.1, Roth

E135.1, Roth

Material: borosilicate glass, PTFE, stainless steel 1.4301. With specially polished syringe hole and PTFE plunger tip. Gas and liquid-tight up to a pressure of 5.0 kg/cm 2 . Technical specifications: tested up to 3.0 bar liquid pressure; calibrated with a ±1% accuracy; precise and easy-to-read scale; exact finishing prevents the creation of air bubbles, as far as possible. Syringe gas-tight with Luer-Lock connection Ideal for applications requiring particular inertness. Not a medical device / Not an IVD product Delivery without needle.

Product Detail
New
H136.1, Roth

H136.1, Roth

Material: stainless steel 1.4301. For Agilent (HP) model 7673A. The models with the super-elastic plungers made from Ni-Ti alloy guarantee a longer useable life. Needle with conical tip, fixed in place. Technical specifications: tested up to 3.0 bar liquid pressure; calibrated with a ±1% accuracy; precise and easy-to-read scale; exact finishing prevents the creation of air bubbles, as far as possible. Microlitre syringe for autosamplers Not a medical device / Not an IVD product

Product Detail
New
E136.1, Roth

E136.1, Roth

Material: borosilicate glass, PTFE, stainless steel 1.4301. With specially polished syringe hole and PTFE plunger tip. Gas and liquid-tight up to a pressure of 5.0 kg/cm 2 . Technical specifications: tested up to 3.0 bar liquid pressure; calibrated with a ±1% accuracy; precise and easy-to-read scale; exact finishing prevents the creation of air bubbles, as far as possible. Syringe gas-tight with Luer-Lock connection Ideal for applications requiring particular inertness. Not a medical device / Not an IVD product Delivery without needle.

Product Detail
allied chemi
  • secure-payment
  • visa
  • american-express
  • master-card

© 2023 Copyright. All Rights Reserved. Unit 19, Euroway House, Roydsdale Way, Bradford, BD4 6SE, UK