Deliver to United Kingdom
0
Products Found: 6
Showing Results For: Counters

Counters



New Items
New
EE53.1, Roth

EE53.1, Roth

Material: metal, chrome-plated. For mechanical counting up to 9999. The counter adds 1 every time a button is pressed. Rotary knob to reset to 0. With holding ring. Weight 66 g. Hand-held counter

Product Detail
New
3KEL.1, Pce

3KEL.1, Pce

For monitoring and analysing microbial contamination in the air, especially in sensitive hygienic areas. Operates according to the impaction principle: Aspirated air meets a culture medium to which microorganisms adhere. The subsequent cultivation in the petri dish shows the microbiological load. Application: pharmaceutical industry (monitoring the number of microorganisms under the laminar flow hood; analysing the cleanliness of a clean-room; testing the effectiveness of sterilisation), food and beverage industry (detection of microbial contamination in the clean-room according to the HACCP concept), hospitals (detection of pathogenic microorganisms in operating theatres, pharmacies, storage rooms or intensive care units), electrical industry (measurement of particles and microbacterial contamination in clean-rooms) Collection head with 300 pores (Ø 0.6 mm), sterilisable; can be used with standard Petri dishes Ø 90 x 13-15 mm; acc. to ISO 14698-1 Volume can be adjusted freely (in 10-litre increments) Option for continuous measurement or cyclical sampling; pause time (max. 99 min.) and number of cycles (max. 99) are also defined here 99 memory spaces for individual setups; 4000 measured values with date, time and volume are saved per memory space; data can be called up on the device Choice of battery or mains operation; with audible alarm in the event of a power outage Airborne germ collector PCE-AS1 Delivery incl. adapter for glass petri dishes with calibration attachment, carrying case, rechargeable battery (7.4 V/Li-Polymer) and mains plug.

Product Detail
New
39EH.1, Pce

39EH.1, Pce

For mobile measurements. For determining the quantity of dirt particles in the air caused, forexample, by combustion, manufacturing, energy production, vehicle engine emissions and the construction industry. Three different methods of counting. Cumulative: adding up the number of particles per measuring channel starting with the largest channel; differential: absolute number of particles per channel; concentration: average number of items per channel (=particle density) Measurement duration can be adjusted or measurement via start/stop button Also sensors for continuous measurement of air temperature, dew point temperature, wet-bulb temperature and relative air humidity Automatic data storage once the measuring process is complete Built-in camera on the back to link the measurement data to image/video material Automatic shutdown can be adjusted (3 to 60 minutes) and deactivated Particle counter PCE-PCO series PCE-PCO 1 For measuring the particle concentration. Delivery incl. zero filter, battery, charger, USB cable, stand and hardshell case.

Product Detail
New
ENK9.1, Roth

ENK9.1, Roth

Mechanical table counter for counting blood cells, bacterial colonies or for other applications in which different samples are be counted repeatedly. Counts individual points up to 999. With summary window to show the total count and an audible signal after total counts of 100. Rotary knob to reset to 0. Multi-position counters Delivery incl. with annotated labels for blood cell count.

Product Detail
New
ENK8.1, Roth

ENK8.1, Roth

Mechanical table counter for counting blood cells, bacterial colonies or for other applications in which different samples are be counted repeatedly. Counts individual points up to 999. With summary window to show the total count and an audible signal after total counts of 100. Rotary knob to reset to 0. Multi-position counters Delivery incl. with annotated labels for blood cell count.

Product Detail
New
39EK.1, Pce

39EK.1, Pce

For mobile measurements. For determining the quantity of dirt particles in the air caused, forexample, by combustion, manufacturing, energy production, vehicle engine emissions and the construction industry. Three different methods of counting. Cumulative: adding up the number of particles per measuring channel starting with the largest channel; differential: absolute number of particles per channel; concentration: average number of items per channel (=particle density) Measurement duration can be adjusted or measurement via start/stop button Also sensors for continuous measurement of air temperature, dew point temperature, wet-bulb temperature and relative air humidity Automatic data storage once the measuring process is complete Built-in camera on the back to link the measurement data to image/video material Automatic shutdown can be adjusted (3 to 60 minutes) and deactivated Particle counter PCE-PCO series PCE-PCO 2 Alongside the particle concentration, you can also determine the mass concentration. There is the PM 2.5 measuring channel (for particles in the 2.5 µm range) and the PM 10 measuring channel (for particles in the 10 µm) range. Delivery incl. zero filter, battery, charger, USB cable, stand and hardshell case.

Product Detail