Benchtop conductivity meters COND 50 VioLab Basic
Order number: HXA8.1
Part number: AC100015005
£ 430.56*
*Prices without VAT and shipping costs£ 516.67*
*incl. VAT, plus shipping costsPrice Breakdown
A staple reagent in organic synthesis and formulation chemistry, the Benchtop Conductivity Meters Cond 50 Violab Basic is an essential tool for measuring conductivity and total dissolved solids (TDS) in various solutions. This instrument boasts a wide measuring range of 0 mg/l to 100 g/l ppt for TDS, and 0 µS/cm to 200 mS/cm for conductivity, making it suitable for a diverse array of applications. With automatic calibration points and resolution settings, users can easily adjust the meter to suit their specific needs. Additionally, the Cond 50 Violab Basic features a temperature measuring range of 0 to +100 °C, ensuring accurate readings across a broad temperature spectrum. Its compact design, BNC (EC) and Cinch (°C) connections, and mains adapter power supply make it a versatile and convenient choice for any laboratory setting.
- Category: Benchtop conductivity meters
- Connection: BNC (EC), Cinch (°C)
- Conductivity resolution: automatic (0.01 µS/cm - 0.1 mS/cm)
- L x W x H: 160 x 185 x 70 mm
- Cell constant: 0,1 / 1,0 / 10 cm -1
- Conductivity accuracy: ±0.4 µS/cm (0 to 19.99 µS/cm) ±4 µS/cm (20.0 to 199.9 µS/cm) ±40 µS/cm (200 to 1999 µS/cm) ±0.4 mS/cm (2.00 to 19.99 mS/cm) ±4 mS/cm (2.00 to 200.0 mS/cm)
- Calibration points: automatic: 1/2/3/4 (standard)manual: 1 (user-defined)
- Conductivity measuring range: 0 µS/cm to 200 mS/cm
| Name | Value | |
|---|---|---|
| Type | : | COND 50 VioLab Basic |
| Sensor | : | none |
| Weight | : | 550 g |
| L x W x H | : | 160 x 185 x 70 mm |
| Connection | : | BNC (EC), Cinch (°C) |
| Parameters | : | conductivity TDS temperature |
| Power supply | : | mains adapter |
| TDS accuracy | : | ±0.2 mg/l (0 to 19.99 mg/l) ±2 mg/l (20.0 to 199.9 mg/l) ±20 mg/l (200 to 1999 mg/l) ±0.2 g/l (2.00 to 19.99 g/l) ±1 g/l (20.0 to 100.0 g/l) |
| Cell constant | : | 0,1 / 1,0 / 10 cm -1 |
| TDS resolution | : | automatic (0.01 mg/l - 0.1 g/l) |
| Calibration points | : | automatic: 1/2/3/4 (standard)manual: 1 (user-defined) |
| TDS measuring range | : | 0 mg/l to 100 g/l ppt |
| Temperature accuracy | : | ±0.5 °C |
| Conductivity accuracy | : | ±0.4 µS/cm (0 to 19.99 µS/cm) ±4 µS/cm (20.0 to 199.9 µS/cm) ±40 µS/cm (200 to 1999 µS/cm) ±0.4 mS/cm (2.00 to 19.99 mS/cm) ±4 mS/cm (2.00 to 200.0 mS/cm) |
| Temperature resolution | : | 0.1 °C |
| Conductivity resolution | : | automatic (0.01 µS/cm - 0.1 mS/cm) |
| Temperature coefficient | : | 0-10,00 %/°C |
| Temperature measuring range | : | 0 to +100 °C |
| Conductivity measuring range | : | 0 µS/cm to 200 mS/cm |
| Reference temperature conductivity | : | +15 - +30 °C |