Benchtop conductivity meters COND 50 VioLab Basic
Order number: HXA8.1
Part number: AC100015005
£ 488.61*
*Prices without VAT and shipping costs£ 586.33*
*incl. VAT, plus shipping costsPrice Breakdown
The Violab Basic benchtop conductivity meter is a reliable tool for measuring the electrical conductivity of various substances in different formats, ensuring precise results every time. With its robust construction and user-friendly interface, this device is perfect for labs and industries where accurate measurements are crucial. By providing automatic calibration options and a wide measuring range, the Violab Basic simplifies complex tasks and saves valuable time.
Why This Benchtop Conductivity Meters Cond 50 Violab Format Works
- Its cell constants come in three configurations: 0.1 cm^-1, 1 cm^-1, and 10 cm^-1, accommodating diverse sample types and measurement needs.
- This instrument boasts impressive accuracy across its broad measuring range of 0 μS/cm to 200 mS/cm, making it suitable for a wide variety of applications.
- The Violab Basic measures conductivity with a high resolution of 0.01 μS/cm to 0.1 mS/cm, ensuring detailed insights into subtle changes in samples.
- Equipped with BNC (EC) and Cinch (°C) connections, this device seamlessly.
Versatile Uses of the Product
Benchtop Conductivity Meters Cond 50 Violab is supplied for Benchtop conductivity meters work where the documented pack format applies.
| Name | Value | |
|---|---|---|
| Type | : | COND 50 VioLab Basic |
| Sensor | : | none |
| Weight | : | 550 g |
| L x W x H | : | 160 x 185 x 70 mm |
| Connection | : | BNC (EC), Cinch (°C) |
| Parameters | : | conductivity TDS temperature |
| Power supply | : | mains adapter |
| TDS accuracy | : | ±0.2 mg/l (0 to 19.99 mg/l) ±2 mg/l (20.0 to 199.9 mg/l) ±20 mg/l (200 to 1999 mg/l) ±0.2 g/l (2.00 to 19.99 g/l) ±1 g/l (20.0 to 100.0 g/l) |
| Cell constant | : | 0,1 / 1,0 / 10 cm -1 |
| TDS resolution | : | automatic (0.01 mg/l - 0.1 g/l) |
| Calibration points | : | automatic: 1/2/3/4 (standard)manual: 1 (user-defined) |
| TDS measuring range | : | 0 mg/l to 100 g/l ppt |
| Temperature accuracy | : | ±0.5 °C |
| Conductivity accuracy | : | ±0.4 µS/cm (0 to 19.99 µS/cm) ±4 µS/cm (20.0 to 199.9 µS/cm) ±40 µS/cm (200 to 1999 µS/cm) ±0.4 mS/cm (2.00 to 19.99 mS/cm) ±4 mS/cm (2.00 to 200.0 mS/cm) |
| Temperature resolution | : | 0.1 °C |
| Conductivity resolution | : | automatic (0.01 µS/cm - 0.1 mS/cm) |
| Temperature coefficient | : | 0-10,00 %/°C |
| Temperature measuring range | : | 0 to +100 °C |
| Conductivity measuring range | : | 0 µS/cm to 200 mS/cm |
| Reference temperature conductivity | : | +15 - +30 °C |