Combi hand-held measuring device PC 7 Vio
Order number: HTE8.1
Part number: AC100014599
£ 682.11*
*Prices without VAT and shipping costs£ 818.53*
*incl. VAT, plus shipping costsPrice Breakdown
Developed for demanding processing applications, the Combi Hand-Held Measuring Device Pc 7 Vio offers versatile measurement capabilities. With sensors for pH and electrical conductivity (EC), it can measure parameters such as redox potential, conductivity, total dissolved solids (TDS), temperature, and more. This compact device features dimensions of 196 x 86 x 33 mm and weighs approximately 300 grams, making it easy to handle during various tasks. It is powered by three Mignon/AA 1.5V batteries and boasts an impressive accuracy of ±0.01 pH for pH measurements and ±0.2 mg/l for TDS measurements within its respective ranges. Additionally, it offers a resolution of 0.1°C for temperature measurements and automatic resolution for TDS measurements between 0.01 mg/l and 0.1 g/l. The device's connectors include BNC for pH and EC, and cinch for temperature measurements, providing flexibility in connecting to different systems.
- Category: Combi hand-held measuring device
- Connection: BNC (pH), BNC (EC), Cinch (°C)
- Cell constant: 0,1 / 1,0 / 10 cm -1
- Channels: 2
- Conductivity measuring range: 0 µS/cm to 200 mS/cm
- Conductivity resolution: automatic (0.01 μS/cm - 0.1 mS/cm)
- Calibration points: 1/2/3 (pH), 1/2/3/4 (EC)
- Conductivity accuracy: ±0.4 μmS/cm (0 to 19.99 μmS/cm) ±4 μmS/cm (20.0 to 199.9 μmS/cm) ±40 μS/cm (200 to 1999 μS/cm) ±0.4 mS/cm (2.00 to 19.99 mS/cm) ±4 mS/cm (20.0 to 200.0 mS/cm)
| Name | Value | |
|---|---|---|
| Type | : | PC 7 Vio |
| Sensor | : | 201T (pH), 2301T (EC) |
| Weight | : | 300 g |
| Channels | : | 2 |
| L x W x H | : | 196 x 86 x 33 mm |
| Connection | : | BNC (pH), BNC (EC), Cinch (°C) |
| Parameters | : | pH redox conductivity TDS temperature |
| pH accuracy | : | ±0.01 pH |
| Power supply | : | 3x battery Mignon/AA 1,5 V |
| TDS accuracy | : | ±0.2 mg/l (0 to 19.99 mg/l) ±2 mg/l (20.0 to 199.9 mg/l) ±20 mg/l (200 to 1999 mg/l) ±0.2 g/l (2.00 to 19.99 g/l) ±1 g/l (20.0 to 100.0 g/l) |
| Cell constant | : | 0,1 / 1,0 / 10 cm -1 |
| pH resolution | : | 0,1 / 0,01 pH |
| TDS resolution | : | automatic (0.01 mg/l - 0.1 g/l) |
| Voltage accuracy | : | ±1 mV |
| Calibration points | : | 1/2/3 (pH), 1/2/3/4 (EC) |
| Voltage resolution | : | 1 mV |
| pH measuring range | : | 0 to 14 |
| TDS measuring range | : | 0 mg/l to 100 g/l ppm |
| Temperature accuracy | : | ±0.5 °C |
| Conductivity accuracy | : | ±0.4 μmS/cm (0 to 19.99 μmS/cm) ±4 μmS/cm (20.0 to 199.9 μmS/cm) ±40 μS/cm (200 to 1999 μS/cm) ±0.4 mS/cm (2.00 to 19.99 mS/cm) ±4 mS/cm (20.0 to 200.0 mS/cm) |
| Temperature resolution | : | 0.1 °C |
| Conductivity resolution | : | automatic (0.01 μS/cm - 0.1 mS/cm) |
| Temperature coefficient | : | 0-10,00 % / °C |
| Voltage measuring range | : | -1000 to +1000 mV |
| Temperature measuring range | : | 0 to +100 °C |
| Conductivity measuring range | : | 0 µS/cm to 200 mS/cm |
| Reference temperature conductivity | : | +15 - +30 °C |