Combi hand-held measuring device SensoDirect 150
Order number: YT94.1
Part number: AC100016010
£ 716.94*
*Prices without VAT and shipping costs£ 860.33*
*incl. VAT, plus shipping costsPrice Breakdown
Adapted for use across diverse chemical handling environments, the Combi Hand-Held Measuring Device Sensodirect 150 offers versatile measurement capabilities. This compact instrument features two channels and sensors for pH and electrical conductivity (EC), enabling simultaneous readings of parameters such as redox potential, total dissolved solids (TDS), oxygen levels, temperature, and conductivity. With an automatic temperature compensation range of 0 to +65°C for pH measurements and up to +100°C for manual adjustments, this device ensures accurate results under varying conditions. The Sensodirect 150 also includes a salt correction function, covering a range of 0-39%, and boasts high resolutions for both pH and TDS measurements. Powered by four Mignon/AA 1.5V batteries, it offers a data memory capacity of 16,000 data sets for convenient storage and analysis.
- Category: Combi hand-held measuring device
- Connection: BNC (pH)
- Calibration points: 1/2/3 (pH, EC), 1 (Redox)
- Conductivity measuring range: 0.2 to 200 mS/cm
- Conductivity accuracy: ±0.01 mS/cm (0.200 to 2.000 mS) ±0.1 mS/cm (2.01 to 20.00 mS) ±1 mS/cm (20.1 to 200.0 mS)
- Air pressure compensation: 0-8900 m
- Channels: 2
- Conductivity resolution: automatic (0.001 S/cm - 0.1 mS/cm)
| Name | Value | |
|---|---|---|
| O | : | automatic: 0 to +50 °C |
| Type | : | SensoDirect 150 |
| Sensor | : | 226 (pH), LC 8 (EC) |
| Weight | : | 625 g |
| Channels | : | 2 |
| L x W x H | : | 220 x 120 x 40 mm |
| Connection | : | BNC (pH) |
| Parameters | : | pH redox conductivity TDS oxygen temperature |
| Data memory | : | 16000 data sets |
| pH accuracy | : | ±0.02 pH |
| Power supply | : | 4x battery Mignon/AA 1.5 V |
| TDS accuracy | : | 2.64 ppm (0 to 132 ppm) 26.4 ppm (132 to 1320 ppm) 264 ppm (1320 to 13,200 ppm) 2640 ppm (13,200 to 132,000 ppm) |
| pH resolution | : | 0,01 pH |
| TDS resolution | : | 0.1 ppm (0 to 132 ppm) 1 ppm (132 to 1320 ppm) 10 ppm (1320 to 13,200 ppm) 100 ppm (13,200 to 132,000 ppm) |
| Salt correction | : | 0-39 % |
| Voltage accuracy | : | ±1 mV |
| Calibration points | : | 1/2/3 (pH, EC), 1 (Redox) |
| Voltage resolution | : | 1 mV mV |
| pH measuring range | : | 0 to 14 |
| TDS measuring range | : | 0 to 132000 ppm |
| Conductivity accuracy | : | ±0.01 mS/cm (0.200 to 2.000 mS) ±0.1 mS/cm (2.01 to 20.00 mS) ±1 mS/cm (20.1 to 200.0 mS) |
| pH temp. compensation | : | automatic: 0 to +65 °C, manual: 0 to +100 °C |
| Conductivity resolution | : | automatic (0.001 S/cm - 0.1 mS/cm) |
| Voltage measuring range | : | -1999 to +1999 mV |
| Air pressure compensation | : | 0-8900 m |
| Conductivity measuring range | : | 0.2 to 200 mS/cm |
| Temperature compensation conductivity | : | automatic: 0 to +60 °C |