Combi table-top multimeter PC 50 VioLab
Order number: HXC0.1
Part number: AC100015079
£ 764.33*
*Prices without VAT and shipping costs£ 917.20*
*incl. VAT, plus shipping costsPrice Breakdown
1
6
24
A reliable solution for controlled synthesis, the Combi Table-Top Multimeter PC 50 VioLab delivers precise measurements across multiple parameters including pH, redox, conductivity, TDS, and temperature. Its delivery includes essential accessories such as the 201T pH single-rod measuring cell, 2301T conductivity sensor, buffer solutions, storage solution, electrode holder, and a mains adapter. With an adjustable reference temperature, cell constant, and temperature coefficient, this multimeter ensures accurate results within its specified ranges.
- Category: Combi table-top multimeter
- Voltage resolution: 1 mV
- TDS accuracy: ±0.2 mg/l (0 to 19.99 mg/l) ±2 mg/l (20.0 to 199.9 mg/l) ±20 mg/l (200 to 1999 mg/l) ±0.2 g/l (2.00 to 19.99 g/l) ±1 g/l (20.0 to 100.0 g/l)
- Parameters: pH redox conductivity TDS temperature
- pH accuracy: ±0.01 pH
- Voltage accuracy: ±1 mV
- Conductivity accuracy: ±0.4 μmS/cm (0 to 19.99 μmS/cm) ±4 μmS/cm (20.0 to 199.9 μmS/cm) ±40 μS/cm (200 to 1999 μS/cm) ±0.4 mS/cm (2.00 to 19.99 mS/cm) ±4 mS/cm (20.0 to 200.0 mS/cm)
- Channels: 2
- TDS measuring range: 0 mg/l to 100 g/l ppm
- Weight: 550 g
- Mains connection: 100-240 V, 50/60 Hz
- Type: PC 50 VioLab
- Reference temperature conductivity: +15 - +30 °C
- Connection: BNC (pH), BNC (EC), Cinch (°C)
- Sensor: 201T (pH), 2301T (EC)
- pH measuring range: 0 to 14
- Temperature resolution: 0.1 °C
- pH resolution: 0,01 pH
- Conductivity resolution: automatic (0.01 μS/cm - 0.1 mS/cm)
- Temperature accuracy: ±0.5 °C
- Voltage measuring range: -1000 to +1000 mV
- Cell constant: 0,1 / 1,0 / 10 cm -1
- Calibration points: 1/2/3 (pH), 1/2/3/4 (EC)
- L x W x H: 160 x 185 x 70 mm
- Temperature coefficient: 0-10,00 % / °C
- Conductivity measuring range: 0 µS/cm to 200 mS/cm
- TDS resolution: automatic (0.01 mg/l - 0.1 g/l)
- Temperature measuring range: 0 to +100 °C
| Name | Value | |
|---|---|---|
| Type | : | PC 50 VioLab |
| Sensor | : | 201T (pH), 2301T (EC) |
| Weight | : | 550 g |
| Channels | : | 2 |
| L x W x H | : | 160 x 185 x 70 mm |
| Connection | : | BNC (pH), BNC (EC), Cinch (°C) |
| Parameters | : | pH redox conductivity TDS temperature |
| pH accuracy | : | ±0.01 pH |
| TDS accuracy | : | ±0.2 mg/l (0 to 19.99 mg/l) ±2 mg/l (20.0 to 199.9 mg/l) ±20 mg/l (200 to 1999 mg/l) ±0.2 g/l (2.00 to 19.99 g/l) ±1 g/l (20.0 to 100.0 g/l) |
| Cell constant | : | 0,1 / 1,0 / 10 cm -1 |
| pH resolution | : | 0,01 pH |
| TDS resolution | : | automatic (0.01 mg/l - 0.1 g/l) |
| Mains connection | : | 100-240 V, 50/60 Hz |
| Voltage accuracy | : | ±1 mV |
| Calibration points | : | 1/2/3 (pH), 1/2/3/4 (EC) |
| Voltage resolution | : | 1 mV |
| pH measuring range | : | 0 to 14 |
| TDS measuring range | : | 0 mg/l to 100 g/l ppm |
| Temperature accuracy | : | ±0.5 °C |
| Conductivity accuracy | : | ±0.4 μmS/cm (0 to 19.99 μmS/cm) ±4 μmS/cm (20.0 to 199.9 μmS/cm) ±40 μS/cm (200 to 1999 μS/cm) ±0.4 mS/cm (2.00 to 19.99 mS/cm) ±4 mS/cm (20.0 to 200.0 mS/cm) |
| Temperature resolution | : | 0.1 °C |
| Conductivity resolution | : | automatic (0.01 μS/cm - 0.1 mS/cm) |
| Temperature coefficient | : | 0-10,00 % / °C |
| Voltage measuring range | : | -1000 to +1000 mV |
| Temperature measuring range | : | 0 to +100 °C |
| Conductivity measuring range | : | 0 µS/cm to 200 mS/cm |
| Reference temperature conductivity | : | +15 - +30 °C |