Data logger LOG200E series, LOG220E
Order number: 1ENE.1
Part number: AC100015008
£ 128.70*
*Prices without VAT and shipping costs£ 154.44*
*incl. VAT, plus shipping costsPrice Breakdown
1
6
24
Engineered for consistent performance in temperature, humidity, pressure, and carbon dioxide measurements, the Data Logger Log220E series stands out among data loggers. Featuring a compact design of 91.5 x 42 x 20 mm and weighing just 83 grams, it offers an impressive data memory capacity of 60,000 measured values. With a USB port for easy connectivity, this device boasts a display for real-time monitoring and comes equipped with a motion sensor that records vibrations. Powered by a 3.6V lithium battery, it operates on a mains connection of 100-240V, 50/60Hz. The Log220E series also supports external sensors, making it versatile for various applications. Included in the delivery is an ISO calibration certificate, wall mount, and battery.
- Category: Data loggers
- Carbon dioxide measuring range (external): 0 to 10000 ppm
- Measuring cycle: 10 s to 24 h
- Rel. humidity resolution: 0,1 %
- Temperature measuring range, internal: -40 to +70 °C
- Min./max. function: yes
- Parameters: temperature humidity pressure carbon dioxide
- Air pressure resolution: 0,1 hPa
- Mains connection: 100-240 V, 50/60 Hz
- Data memory: 60 000 measured values
- L x W x D: 91.5 x 42 x 20 mm
- Display: yes
- Temperature measuring range: -200 to +850 °C
- Power supply: 3.6 V/ 1 / 2 AA lithium battery
- Port: USB
- Type: LOG220E
- Temperature accuracy: ±0.5 °C (0 to +60 °C) ±1.0 °C (outside)
- Rel. humidity measuring range: 0 to 100 %
- Carbon dioxide accuracy: ±30 ppm +3% of measured value (23 °C)
- Rel. humidity accuracy: ±3.5% (20 to 80%) ±5% (outside)
- Weight: 83 g
- Ext. temp. measuring range: -200 to +850 °C
- Air pressure accuracy: ±1.0 hPa (900 to 1100 hPa) ±5.5 hPa (outside)
- Air pressure measuring range: 300–1100 hPa
- Temperature resolution: 0.1 °C
| Name | Value | |
|---|---|---|
| Port | : | USB |
| Type | : | LOG220E |
| Weight | : | 83 g |
| Display | : | yes |
| L x W x D | : | 91.5 x 42 x 20 mm |
| Parameters | : | temperature humidity pressure carbon dioxide |
| Data memory | : | 60 000 measured values |
| Power supply | : | 3.6 V/ 1 / 2 AA lithium battery |
| Measuring cycle | : | 10 s to 24 h |
| Mains connection | : | 100-240 V, 50/60 Hz |
| Min./max. function | : | yes |
| Temperature accuracy | : | ±0.5 °C (0 to +60 °C) ±1.0 °C (outside) |
| Air pressure accuracy | : | ±1.0 hPa (900 to 1100 hPa) ±5.5 hPa (outside) |
| Rel. humidity accuracy | : | ±3.5% (20 to 80%) ±5% (outside) |
| Temperature resolution | : | 0.1 °C |
| Air pressure resolution | : | 0,1 hPa |
| Carbon dioxide accuracy | : | ±30 ppm +3% of measured value (23 °C) |
| Rel. humidity resolution | : | 0,1 % |
| Ext. temp. measuring range | : | -200 to +850 °C |
| Temperature measuring range | : | -200 to +850 °C |
| Air pressure measuring range | : | 300–1100 hPa |
| Rel. humidity measuring range | : | 0 to 100 % |
| Temperature measuring range, internal | : | -40 to +70 °C |
| Carbon dioxide measuring range (external) | : | 0 to 10000 ppm |