SPE polypropylene columns ROTI ® X Bond WCX, 6 ml, 500 mg, 30 unit(s)
Order number: 24L5.1
Part number: AC100006827
£ 295.11*
*Prices without VAT and shipping costs£ 354.13*
*incl. VAT, plus shipping costsPrice Breakdown
1
6
24
Produced to ensure dependable processing results, Spe Polypropylene Columns Roti ® X Bond Wcx belong to the ion exchangers for the SPE category within the broader chromatography labware. These open tubular syringe-shaped columns with Luer tip outlets are made of PP material with PE filter elements, offering a specific surface area of 600 m²/g as per BET. Filled with 500 mg of carboxylic acid-modified spherical polystyrene/divinylbenzene copolymer, they function as a weak acidic cation exchanger (mixed mode), making them ideal for the enrichment of strong basic analytes (pKa >10) in samples such as urine, plasma, and serum. With a pH stability range of 1.0-14.0, these columns offer versatile applications while maintaining
- Category: Ion exchangers for the SPE
- Specific surface according to BET: 600 m²/g
- Pore size: 300 Å
- Separation principle: Mixed mode (RP and Ion exchange (IEX))
- Recommended storage temperature: RT
- Packaging: 6 x 5 units
- Similar phases: Oasis ® WCX Strata™-X-CW CHROMABOND ® HR-XCW Copure ® WCX
- Material text: Material: PP columns with PE filter elements.
- pH stability: 1,0-14,0
- Particle type: Fully porous particles (FPP)
- Phase: WCX
- pK: ~5
- Recommended application(s): Strong bases with pK a >10 Basic active ingredients from strongly matrix-contaminated samples like e.g. urine, plasma, serum
- Column type: SPE column
- Column shape: Open tubular syringe-shaped column with Luer tip outlet
- Surface chemistry: Hydrophobic spherical polystyrene-divinylbenzene copolymer (PS/DVB) with carboxylic acid modification, weak mixed mode cation exchanger (WCX)
- Column volume: 6 ml
- Filling quantity: 500 mg
- Particle size: 40 µm
| Name | Value | |
|---|---|---|
| pK | : | ~5 |
| Phase | : | WCX |
| Packaging | : | 6 x 5 units |
| Pore size | : | 300 Å |
| Column type | : | SPE column |
| Column shape | : | Open tubular syringe-shaped column with Luer tip outlet |
| pH stability | : | 1,0-14,0 |
| Column volume | : | 6 ml |
| Material text | : | Material: PP columns with PE filter elements. |
| Particle size | : | 40 µm |
| Particle type | : | Fully porous particles (FPP) |
| Similar phases | : | Oasis ® WCX Strata™-X-CW CHROMABOND ® HR-XCW Copure ® WCX |
| Filling quantity | : | 500 mg |
| Surface chemistry | : | Hydrophobic spherical polystyrene-divinylbenzene copolymer (PS/DVB) with carboxylic acid modification, weak mixed mode cation exchanger (WCX) |
| Separation principle | : | Mixed mode (RP and Ion exchange (IEX)) |
| Recommended application(s) | : | Strong bases with pK a >10 Basic active ingredients from strongly matrix-contaminated samples like e.g. urine, plasma, serum |
| Recommended storage temperature | : | RT |
| Specific surface according to BET | : | 600 m²/g |
