Notable for its clearly defined purity profile and consistent composition, the Portable Conductivity Meters Cond 7 Vio Set is designed for precise measurements of conductivity, TDS, and temperature. This compact instrument features a Type COND 7 Vio Set sensor and a connection via BNC (EC) Cinch (°C), making it suitable for various applications. It operates on three batteries Mignon/AA 1.5 V and offers an automatic calibration system with four standard calibration points, as well as a user-defined option. The Cond 7 Vio Set boasts high accuracy in both TDS and conductivity measurements, with resolutions ranging from 0.01 mg/l to 0.1 g/l and 0.01 µS/cm to 0.1 mS/cm, respectively. Additionally, it provides a temperature accuracy of ±0.5 °C and a temperature measuring range of 0 to +100 °C. This portable device is an ideal choice for professionals requiring reliable and accurate measurements in their work.
- Category: Portable conductivity meters
- Connection: BNC (EC) Cinch (°C)
- Calibration points: automatic: 1/2/3/4 (standard)manual: 1 (user-defined)
- L x W x H: 196 x 86 x 33 mm
- Conductivity measuring range: 0 µS/cm to 200 mS/cm
- Conductivity resolution: automatic (0.01 µS/cm - 0.1 mS/cm)
- Conductivity accuracy: ±0.4 µS/cm (0 to 19.99 µS/cm) ±4 µS/cm (20.0 to 199.9 µS/cm) ±40 µS/cm (200 to 1999 µS/cm) ±0.4 mS/cm (2.00 to 19.99 mS/cm) ±4 mS/cm (20.0 to 200.0 mS/cm)
- Cell constant: 0,1 / 1,0 / 10 cm -1
| Name | Value | |
|---|---|---|
| Type | : | COND 7 Vio Set |
| Sensor | : | 2301T |
| Weight | : | 300 g |
| L x W x H | : | 196 x 86 x 33 mm |
| Connection | : | BNC (EC) Cinch (°C) |
| Parameters | : | conductivity TDS temperature |
| Power supply | : | 3x battery Mignon/AA 1.5 V |
| TDS accuracy | : | ±0.2 mg/l (0 to 19.99 mg/l) ±2 mg/l (20.0 to 199.9 mg/l) ±20 mg/l (200 to 1999 mg/l) ±0.2 g/l (2.00 to 19.99 g/l) ±1 g/l (20.0 to 100.0 g/l) |
| Cell constant | : | 0,1 / 1,0 / 10 cm -1 |
| TDS resolution | : | automatic (0.01 mg/l - 0.1 g/l) |
| Calibration points | : | automatic: 1/2/3/4 (standard)manual: 1 (user-defined) |
| TDS measuring range | : | 0 mg/l to 100 g/l ppt |
| Temperature accuracy | : | ±0.5 °C |
| Conductivity accuracy | : | ±0.4 µS/cm (0 to 19.99 µS/cm) ±4 µS/cm (20.0 to 199.9 µS/cm) ±40 µS/cm (200 to 1999 µS/cm) ±0.4 mS/cm (2.00 to 19.99 mS/cm) ±4 mS/cm (20.0 to 200.0 mS/cm) |
| Temperature resolution | : | 0.1 °C |
| Conductivity resolution | : | automatic (0.01 µS/cm - 0.1 mS/cm) |
| Temperature coefficient | : | 0-10,00 %/°C |
| Temperature measuring range | : | 0 to +100 °C |
| Conductivity measuring range | : | 0 µS/cm to 200 mS/cm |
| Reference temperature conductivity | : | +15 - +30 °C |