Portable conductivity meters COND 7 Vio Basic
Order number: HPL7.1
Part number: AC100015645
£ 280.58*
*Prices without VAT and shipping costs£ 336.70*
*incl. VAT, plus shipping costsPrice Breakdown
1
6
24
Designed for professional use, the Portable Conductivity Meters Cond 7 Vio Basic comes packaged with a large LCD display, test solutions, measuring beaker, storage case, and batteries. This compact device boasts an automatic calibration feature, displaying calibrated ranges, and offers temperature correction from 0 to +100 °C, manually adjustable up to +80 °C. It features a portable design, weighing just 300g, with dimensions of 196 x 86 x 33mm, making it easy to carry around. With its BNC connection, this meter measures both conductivity and temperature parameters, powered by three Mignon/AA 1.5V batteries.
- Category: Portable conductivity meters
- TDS measuring range: 0 mg/l to 100 g/l ppt
- Conductivity accuracy: ±0.4 µS/cm (0 to 19.99 µS/cm) ±4 µS/cm (20.0 to 199.9 µS/cm) ±40 µS/cm (200 to 1999 µS/cm) ±0.4 mS/cm (2.00 to 19.99 mS/cm) ±4 mS/cm (20.0 to 200.0 mS/cm)
- Type: COND 7 Vio Basic
- Temperature measuring range: 0 to +100 °C
- Parameters: conductivity TDS temperature
- Temperature coefficient: 0-10,00 %/°C
- Conductivity resolution: automatic (0.01 µS/cm - 0.1 mS/cm)
- TDS accuracy: ±0.2 mg/l (0 to 19.99 mg/l) ±2 mg/l (20.0 to 199.9 mg/l) ±20 mg/l (200 to 1999 mg/l) ±0.2 g/l (2.00 to 19.99 g/l) ±1 g/l (20.0 to 100.0 g/l)
- L x W x H: 196 x 86 x 33 mm
- Temperature accuracy: ±0.5 °C
- Weight: 300 g
- Calibration points: automatic: 1/2/3/4 (standard)manual: 1 (user-defined)
- Sensor: none
- Temperature resolution: 0.1 °C
- Connection: BNC (EC) Cinch (°C)
- Conductivity measuring range: 0 µS/cm to 200 mS/cm
- Reference temperature conductivity: +15 - +30 °C
- Cell constant: 0,1 / 1,0 / 10 cm -1
- Power supply: 3x battery Mignon/AA 1.5 V
- TDS resolution: automatic (0.01 mg/l - 0.1 g/l)
| Name | Value | |
|---|---|---|
| Type | : | COND 7 Vio Basic |
| Sensor | : | none |
| Weight | : | 300 g |
| L x W x H | : | 196 x 86 x 33 mm |
| Connection | : | BNC (EC) Cinch (°C) |
| Parameters | : | conductivity TDS temperature |
| Power supply | : | 3x battery Mignon/AA 1.5 V |
| TDS accuracy | : | ±0.2 mg/l (0 to 19.99 mg/l) ±2 mg/l (20.0 to 199.9 mg/l) ±20 mg/l (200 to 1999 mg/l) ±0.2 g/l (2.00 to 19.99 g/l) ±1 g/l (20.0 to 100.0 g/l) |
| Cell constant | : | 0,1 / 1,0 / 10 cm -1 |
| TDS resolution | : | automatic (0.01 mg/l - 0.1 g/l) |
| Calibration points | : | automatic: 1/2/3/4 (standard)manual: 1 (user-defined) |
| TDS measuring range | : | 0 mg/l to 100 g/l ppt |
| Temperature accuracy | : | ±0.5 °C |
| Conductivity accuracy | : | ±0.4 µS/cm (0 to 19.99 µS/cm) ±4 µS/cm (20.0 to 199.9 µS/cm) ±40 µS/cm (200 to 1999 µS/cm) ±0.4 mS/cm (2.00 to 19.99 mS/cm) ±4 mS/cm (20.0 to 200.0 mS/cm) |
| Temperature resolution | : | 0.1 °C |
| Conductivity resolution | : | automatic (0.01 µS/cm - 0.1 mS/cm) |
| Temperature coefficient | : | 0-10,00 %/°C |
| Temperature measuring range | : | 0 to +100 °C |
| Conductivity measuring range | : | 0 µS/cm to 200 mS/cm |
| Reference temperature conductivity | : | +15 - +30 °C |