Order number: 38P9.1
Part number: AC100007546
Recommended for applications requiring controlled solvent behavior, such as high-performance liquid chromatography (HPLC), the Hplc Guard Columns (Analytical) Nucleodur ® C 18 Pyramid offer effective protection against contaminants that may harm the main HPLC column. With a particle size of 5 μm and a pore size of 110 Å, these fully porous particles (FPP) provide a specific surface area of 340 m²/g, ensuring optimal separation efficiency. The reversed phase (RP) separation principle, combined with octadecyl (C 18, ODS) modification and polar endcapping, ensures excellent compatibility with acetonitrile-water eluents. Furthermore, the pyramid structure enhances the durability of the column under pressures up to 600 bar, making it suitable for various analyt
| Name | Value | |
|---|---|---|
| Endcapped | : | yes |
| Pore size | : | 110 Å |
| Pore volume | : | 0.9 ml/g |
| pH stability | : | 1,0-9,0 |
| Column length | : | 4 mm |
| Particle size | : | 5 µm |
| Particle type | : | Fully porous particles (FPP) |
| Carbon content | : | 14 % |
| Eluent in column | : | Acetonitrile - Water |
| Surface chemistry | : | Octadecyl (C 18 , ODS) modification, Polar endcapping |
| Pressure stability | : | 600 bar |
| Separation principle | : | Reversed phase (RP) |
| Column inner diameter | : | 2 mm |
| L x Ø internal (column) | : | 4 x 2 mm |
| Specific surface according to BET | : | 340 m²/g |
© 2026 Copyright. All Rights Reserved.