HPLC column NUCLEODUR ® Phenyl-Hexyl, 1.8 µm, 50 mm, 2 mm
Order number: 34L6.1
Part number: AC100007135
£ 686.93*
*Prices plus VAT plus shipping costs£ 824.32*
*incl. VAT, plus shipping costsPrice Breakdown
1
6
24
Prepared for use in regulated laboratory conditions, the Hplc Column Nucleodur ® Phenyl-Hexyl, 1.8 μm, 50 mm, 2 mm features a reversed phase (RP) separation principle that utilizes both π-π interactions and hydrophobic interactions. With a particle size of 1.8 μm, it offers excellent pressure stability up to 900 bar and temperature stability up to 60°C. The column's specific surface area, as per BET, is 340 m²/g, making it ideal for separating aromatic and unsaturated compounds, antibiotics, pharmaceutical products, steroids, and other polar compounds. It is compatible with acetonitrile-water eluents and is particularly suited for LC-MS applications due to its low bleeding characteristics. The column comes with a
- Category: Separation columns for HPLC
- Column type: UHPLC column
- Endcapped: yes
- Column shape: Analytical separation column
- Separation principle: Reversed phase (RP)
- Interactions / retention mechanism: π-π and hydrophobic
- Eluent in column: Acetonitrile - Water
- Particle type: Fully porous particles (FPP)
- Pore volume: 0.9 ml/g
- Recommended application(s): Antibiotics Aromatic and unsaturated compounds Suitable for LC-MS Pharmaceutical products Especially for polar compounds Steroids
- Application Database (Macherey-Nagel): HPLC
- Pressure stability: 900 bar
- Phase: Phenyl-Hexyl
- Surface chemistry: Phenylhexyl modification
- L x Ø internal (column): 50 x 2 mm
- pH stability: 1,0-10,0
- Pore size: 110 Å
- Temperature stability: 60 ° C
- USP listing: L11
- Particle size: 1.8 µm
- Specific surface according to BET: 340 m²/g
- Column volume: 0.15 ml
| Name | Value | |
|---|---|---|
| Phase | : | Phenyl-Hexyl |
| Endcapped | : | yes |
| Pore size | : | 110 Å |
| Column type | : | UHPLC column |
| Pore volume | : | 0.9 ml/g |
| USP listing | : | L11 |
| Column shape | : | Analytical separation column |
| pH stability | : | 1,0-10,0 |
| Column volume | : | 0.15 ml |
| Particle size | : | 1.8 µm |
| Particle type | : | Fully porous particles (FPP) |
| Eluent in column | : | Acetonitrile - Water |
| Surface chemistry | : | Phenylhexyl modification |
| Pressure stability | : | 900 bar |
| Separation principle | : | Reversed phase (RP) |
| Temperature stability | : | 60 ° C |
| L x Ø internal (column) | : | 50 x 2 mm |
| Recommended application(s) | : | Antibiotics Aromatic and unsaturated compounds Suitable for LC-MS Pharmaceutical products Especially for polar compounds Steroids |
| Specific surface according to BET | : | 340 m²/g |
| Interactions / retention mechanism | : | π-π and hydrophobic |
| Application Database (Macherey-Nagel) | : | HPLC |