HPLC column NUCLEODUR ® Phenyl-Hexyl, 3 µm, 150 mm, 3 mm
Order number: 34N9.1
Part number: AC100007199
£ 788.54*
*Prices plus VAT plus shipping costs£ 946.25*
*incl. VAT, plus shipping costsPrice Breakdown
1
6
24
Suitable for laboratory and industrial environments, the Hplc Column Nucleodur ® Phenyl-Hexyl, 3 μm, 150 mm, 3 mm features a reversed phase (RP) separation principle that utilizes both π-π interactions and hydrophobic interactions for efficient separation. With a particle size of 3 μm, fully porous particles (FPP), and a pore size of 110 Å, this analytical separation column offers excellent pressure stability up to 600 bar and temperature stability up to 60 °C. Its surface chemistry is based on phenylhexyl modification, making it particularly suitable for separating aromatic and unsaturated compounds, antibiotics, pharmaceutical products, steroids, and even for use in LC-MS applications. The column's specific surface area, as determined by BET, is 3
- Category: Separation columns for HPLC
- Separation principle: Reversed phase (RP)
- Temperature stability: 60 ° C
- Application Database (Macherey-Nagel): HPLC
- Pore size: 110 Å
- Eluent in column: Acetonitrile - Water
- Surface chemistry: Phenylhexyl modification
- Particle size: 3 µm
- Specific surface according to BET: 340 m²/g
- Particle type: Fully porous particles (FPP)
- USP listing: L11
- Interactions / retention mechanism: π-π and hydrophobic
- Column volume: 1.05 ml
- Pressure stability: 600 bar
- L x Ø internal (column): 150 x 3 mm
- Recommended application(s): Antibiotics Aromatic and unsaturated compounds Suitable for LC-MS Pharmaceutical products Especially for polar compounds Steroids
- Endcapped: yes
- pH stability: 1,0-10,0
- Phase: Phenyl-Hexyl
- Column shape: Analytical separation column
- Column type: HPLC column
- Pore volume: 0.9 ml/g
| Name | Value | |
|---|---|---|
| Phase | : | Phenyl-Hexyl |
| Endcapped | : | yes |
| Pore size | : | 110 Å |
| Column type | : | HPLC column |
| Pore volume | : | 0.9 ml/g |
| USP listing | : | L11 |
| Column shape | : | Analytical separation column |
| pH stability | : | 1,0-10,0 |
| Column volume | : | 1.05 ml |
| Particle size | : | 3 µm |
| Particle type | : | Fully porous particles (FPP) |
| Eluent in column | : | Acetonitrile - Water |
| Surface chemistry | : | Phenylhexyl modification |
| Pressure stability | : | 600 bar |
| Separation principle | : | Reversed phase (RP) |
| Temperature stability | : | 60 ° C |
| L x Ø internal (column) | : | 150 x 3 mm |
| Recommended application(s) | : | Antibiotics Aromatic and unsaturated compounds Suitable for LC-MS Pharmaceutical products Especially for polar compounds Steroids |
| Specific surface according to BET | : | 340 m²/g |
| Interactions / retention mechanism | : | π-π and hydrophobic |
| Application Database (Macherey-Nagel) | : | HPLC |
