HPLC column NUCLEOSHELL ® Biphenyl, 50 mm, 4 mm
Order number: 367N.1
Part number: AC100007235
£ 711.14*
*Prices plus VAT plus shipping costs£ 853.37*
*incl. VAT, plus shipping costsPrice Breakdown
1
6
24
Structured to assist in consistent experimental procedures, the Hplc Column Nucleoshell ® Biphenyl, 50 Mm, 4 Mm falls within the category of Separation columns for HPLC. Featuring a biphenyl phase and iso-butyl sidechains, this reversed phase column offers improved retention of aromatic and unsaturated substances through π-π interactions and hydrophobic interactions. Its core-shell technology ensures stability in 100% aqueous mobile phases, making it suitable for applications such as antibiotics, aromatic and unsaturated compounds, DNPH aldehydes, hormones, mycotoxins, pesticides, pharmaceutical products, phthalates, and is also compatible with LC-MS. With a pressure stability of 600 bar and temperature stability up to 60° C
- Category: Separation columns for HPLC
- Particle size: 2.7 µm
- Column volume: 0.62 ml
- Interactions / retention mechanism: π-π and hydrophobic
- Endcapped: yes
- USP listing: L11
- Phase: Biphenyl
- L x Ø internal (column): 50 x 4 mm
- Specific surface according to BET: 130 m²/g
- Pressure stability: 600 bar
- Separation principle: Reversed phase (RP)
- Surface chemistry: Biphenylpropyl modification
- Application Database (Macherey-Nagel): HPLC
- Pore size: 90 Å
- Column shape: Analytical separation column
- Eluent in column: Acetonitrile - Water
- Recommended application(s): Antibiotics Aromatic and unsaturated compounds DNPH Aldehydes hormones Mycotoxins Pesticides Pharmaceutical products Phthalates Suitable for LC-MS
- Particle type: Core-shell, superficially porous particles (SPP)
- Pore volume: 0.9 ml/g
- Temperature stability: 60 ° C
- Column type: HPLC column
- pH stability: 1,5-8,5
| Name | Value | |
|---|---|---|
| Phase | : | Biphenyl |
| Endcapped | : | yes |
| Pore size | : | 90 Å |
| Column type | : | HPLC column |
| Pore volume | : | 0.9 ml/g |
| USP listing | : | L11 |
| Column shape | : | Analytical separation column |
| pH stability | : | 1,5-8,5 |
| Column volume | : | 0.62 ml |
| Particle size | : | 2.7 µm |
| Particle type | : | Core-shell, superficially porous particles (SPP) |
| Eluent in column | : | Acetonitrile - Water |
| Surface chemistry | : | Biphenylpropyl modification |
| Pressure stability | : | 600 bar |
| Separation principle | : | Reversed phase (RP) |
| Temperature stability | : | 60 ° C |
| L x Ø internal (column) | : | 50 x 4 mm |
| Recommended application(s) | : | Antibiotics Aromatic and unsaturated compounds DNPH Aldehydes hormones Mycotoxins Pesticides Pharmaceutical products Phthalates Suitable for LC-MS |
| Specific surface according to BET | : | 130 m²/g |
| Interactions / retention mechanism | : | π-π and hydrophobic |