HPLC column NUCLEODUR ® C 18 HTec, 1.8 µm, 50 mm, 4 mm
Order number: 358E.1
Part number: AC100007245
£ 686.93*
*Prices plus VAT plus shipping costs£ 824.32*
*incl. VAT, plus shipping costsPrice Breakdown
1
6
24
Suitable for laboratory and industrial environments, the Hplc Column Nucleodur® C 18 Htec, 1.8 μm, 50 mm, 4 mm is an ideal choice for liquid chromatography applications due to its high loadability and excellent stability. This UHPLC column, featuring fully porous particles (FPP) and a reversed phase (RP) separation principle, offers a specific surface area of 340 m²/g and a pore size of 110 Å. With a particle size of 1.8 μm and a pressure stability of 900 bar, it is suitable for a wide range of applications including aldehydes, fat-soluble vitamins, phenolic compounds, and derivatized amino acids. Its surface chemistry, base deactivated (BDS) and high density octadecyl (
- Category: Separation columns for HPLC
- Particle size: 1.8 µm
- Column volume: 0.62 ml
- Separation principle: Reversed phase (RP)
- Pressure stability: 900 bar
- Recommended application(s): Aldehydes Applications at extreme pH values (1-11) Alkaline, neutral and acidic pharmaceuticals Derivatised amino acids Fat-soluble vitamins Suitable for LC-MS High loading capacity Ketones Pesticides Phenolic compounds
- Surface chemistry: Base deactivated (BDS), High density octadecyl (C 18 , ODS) modification
- USP listing: L1
- pH stability: 1,0-11,0
- Interactions / retention mechanism: hydrophobic (van der Waals)
- Specific surface according to BET: 340 m²/g
- L x Ø internal (column): 50 x 4 mm
- Phase: C 18 HTec
- Endcapped: yes
- Pore size: 110 Å
- Column shape: Analytical separation column
- Temperature stability: 60 ° C
- Eluent in column: Acetonitrile - Water
- Column type: UHPLC column
- Pore volume: 0.9 ml/g
- Particle type: Fully porous particles (FPP)
| Name | Value | |
|---|---|---|
| Phase | : | C 18 HTec |
| Endcapped | : | yes |
| Pore size | : | 110 Å |
| Column type | : | UHPLC column |
| Pore volume | : | 0.9 ml/g |
| USP listing | : | L1 |
| Column shape | : | Analytical separation column |
| pH stability | : | 1,0-11,0 |
| Column volume | : | 0.62 ml |
| Particle size | : | 1.8 µm |
| Particle type | : | Fully porous particles (FPP) |
| Eluent in column | : | Acetonitrile - Water |
| Surface chemistry | : | Base deactivated (BDS), High density octadecyl (C 18 , ODS) modification |
| Pressure stability | : | 900 bar |
| Separation principle | : | Reversed phase (RP) |
| Temperature stability | : | 60 ° C |
| L x Ø internal (column) | : | 50 x 4 mm |
| Recommended application(s) | : | Aldehydes Applications at extreme pH values (1-11) Alkaline, neutral and acidic pharmaceuticals Derivatised amino acids Fat-soluble vitamins Suitable for LC-MS High loading capacity Ketones Pesticides Phenolic compounds |
| Specific surface according to BET | : | 340 m²/g |
| Interactions / retention mechanism | : | hydrophobic (van der Waals) |