HPLC column NUCLEODUR ® C 18 HTec, 5 µm, 250 mm, 21 mm
Order number: 36E6.1
Part number: AC100007246
£ 2491.34*
*Prices plus VAT plus shipping costs£ 2989.61*
*incl. VAT, plus shipping costsPrice Breakdown
1
6
24
Intended for structured formulation workflows, the Hplc Column Nucleodur® C 18 Htec, 5 μm, 250 mm, 21 mm is a valuable addition to any lab working with separation columns for HPLC. This column features a C 18 HTec phase, endcapped particles, and a specific surface area of 340 m²/g, making it ideal for separating a wide range of compounds including aldehydes, fat-soluble vitamins, and phenolic compounds. With a pressure stability of 400 bar and temperature stability of 60° C, this column can handle demanding conditions while maintaining its performance. Its large pore volume of 0.9 ml/g ensures high loadability, making it suitable for both analytical and preparative applications. Additionally, the column's pH stability ranges from
- Category: Separation columns for HPLC
- Recommended application(s): Aldehydes Applications at extreme pH values (1-11) Alkaline, neutral and acidic pharmaceuticals Derivatised amino acids Fat-soluble vitamins Suitable for LC-MS High loading capacity Ketones Pesticides Phenolic compounds
- Particle size: 5 µm
- Column volume: 87 ml
- USP listing: L1
- Temperature stability: 60 ° C
- L x Ø internal (column): 250 x 21 mm
- Specific surface according to BET: 340 m²/g
- Separation principle: Reversed phase (RP)
- Particle type: Fully porous particles (FPP)
- Pressure stability: 400 bar
- Endcapped: yes
- Eluent in column: Acetonitrile - Water
- Phase: C 18 HTec
- Pore size: 110 Å
- Surface chemistry: Base deactivated (BDS), High density octadecyl (C 18 , ODS) modification
- Column type: HPLC column
- Column shape: Preparative separation column
- Application Database (Macherey-Nagel): HPLC
- Interactions / retention mechanism: hydrophobic (van der Waals)
- pH stability: 1,0-11,0
- Pore volume: 0.9 ml/g
| Name | Value | |
|---|---|---|
| Phase | : | C 18 HTec |
| Endcapped | : | yes |
| Pore size | : | 110 Å |
| Column type | : | HPLC column |
| Pore volume | : | 0.9 ml/g |
| USP listing | : | L1 |
| Column shape | : | Preparative separation column |
| pH stability | : | 1,0-11,0 |
| Column volume | : | 87 ml |
| Particle size | : | 5 µm |
| Particle type | : | Fully porous particles (FPP) |
| Eluent in column | : | Acetonitrile - Water |
| Surface chemistry | : | Base deactivated (BDS), High density octadecyl (C 18 , ODS) modification |
| Pressure stability | : | 400 bar |
| Separation principle | : | Reversed phase (RP) |
| Temperature stability | : | 60 ° C |
| L x Ø internal (column) | : | 250 x 21 mm |
| Recommended application(s) | : | Aldehydes Applications at extreme pH values (1-11) Alkaline, neutral and acidic pharmaceuticals Derivatised amino acids Fat-soluble vitamins Suitable for LC-MS High loading capacity Ketones Pesticides Phenolic compounds |
| Specific surface according to BET | : | 340 m²/g |
| Interactions / retention mechanism | : | hydrophobic (van der Waals) |
| Application Database (Macherey-Nagel) | : | HPLC |