Deliver to United Kingdom
0

HPLC column NUCLEODUR ® PolarTec, 3 µm, 50 mm, 4 mm

Order number: 34H4.1

Part number: AC100007278

£ 686.93*

*Prices plus VAT plus shipping costs

£ 824.32*

*incl. VAT, plus shipping costs
In Stock

Price Breakdown

1

6

24

Designed for professional use, the Hplc Column Nucleodur ® Polartec offers exceptional performance under high aqueous conditions. With its unique combination of hydrophobic C18 modification and embedded polar group, it exhibits both steric and enhanced polar selectivity. This makes it particularly suitable for separating polar compounds such as amino acids, basic pharmaceuticals, nitrogen-containing compounds, organic acids, pesticides, phenols, water-soluble vitamins, and even for 100% aqueous eluents. Additionally, its low bleeding characteristics make it ideal for LC/MS applications. The column features a particle size of 3 μm, a specific surface area of 340 m²/g, and a pressure stability of up to 600 bar. Its temperature stability extends to 60°C, making it versatile

  • Category: Separation columns for HPLC
  • Pore size: 110 Å
  • Specific surface according to BET: 340 m²/g
  • Temperature stability: 60 ° C
  • USP listing: L1 L60
  • Particle type: Fully porous particles (FPP)
  • pH stability: 1,0-9,0
  • Pressure stability: 600 bar
  • Column shape: Analytical separation column
  • Eluent in column: Acetonitrile - Water
  • Separation principle: Reversed phase (RP)
  • Phase: PolarTec
  • Interactions / retention mechanism: hydrophobic and polar (H bonds)
  • Particle size: 3 µm
  • Endcapped: yes
  • Column type: HPLC column
  • Surface chemistry: Octadecyl phase (C 18 , ODS) modification, with embedded polar group (PEG)
  • Pore volume: 0.9 ml/g
  • Recommended application(s): Amino acids Basic pharmaceuticals Especially for polar compounds Nitrogen containing compounds Organic acids Pesticides Phenols Suitable for 100 % aqueous eluents Suitable for LC-MS Water-soluble vitamins
  • L x Ø internal (column): 50 x 4 mm
  • Column volume: 0.62 ml