HPLC column NUCLEODUR ® C 18 Isis, 5 µm, 125 mm, 4.6 mm
Order number: 348Y.1
Part number: AC100007302
£ 696.60*
*Prices plus VAT plus shipping costs£ 835.92*
*incl. VAT, plus shipping costsPrice Breakdown
1
6
24
Recommended for applications requiring controlled solvent behavior, such as the separation of positional and structural isomers, planar/non-planar molecules, steroids, fat-soluble vitamins, and (o,p,m)-substituted aromatics, the HPLC column NUCLEODUR ® C 18 Isis offers exceptional steric selectivity. With its nonpolar crosslinked polymeric octadecyl (C 18, ODS) modification, this column provides high steric selectivity and is suitable for LC-MS. Featuring a particle size of 5 μm, it has a pressure stability of 600 bar and a temperature stability of 60 °C. The column's specific surface area, according to BET, is 340 m²/g, making it an ideal choice for various demanding HPLC applications
- Category: Separation columns for HPLC
- Endcapped: yes
- Pressure stability: 600 bar
- Pore volume: 0.9 ml/g
- Surface chemistry: Nonpolar crosslinked polymeric octadecyl (C 18 , ODS) modification, High steric selectivity
- Specific surface according to BET: 340 m²/g
- Eluent in column: Acetonitrile - Water
- Column type: HPLC column
- Phase: C 18 Isis
- Recommended application(s): Separation of positional and structural isomers Planar/non-planar molecules Steroids Suitable for LC-MS (o,p,m-)Substituted aromatics Fat-soluble vitamins Exceptional steric selectivity
- Interactions / retention mechanism: steric and hydrophobic
- Pore size: 110 Å
- USP listing: L1
- Particle type: Fully porous particles (FPP)
- Separation principle: Reversed phase (RP)
- Column shape: Analytical separation column
- Particle size: 5 µm
- pH stability: 1,0-10,0
- L x Ø internal (column): 125 x 4.6 mm
- Column volume: 2.06 ml
- Temperature stability: 60 ° C
| Name | Value | |
|---|---|---|
| Phase | : | C 18 Isis |
| Endcapped | : | yes |
| Pore size | : | 110 Å |
| Column type | : | HPLC column |
| Pore volume | : | 0.9 ml/g |
| USP listing | : | L1 |
| Column shape | : | Analytical separation column |
| pH stability | : | 1,0-10,0 |
| Column volume | : | 2.06 ml |
| Particle size | : | 5 µm |
| Particle type | : | Fully porous particles (FPP) |
| Eluent in column | : | Acetonitrile - Water |
| Surface chemistry | : | Nonpolar crosslinked polymeric octadecyl (C 18 , ODS) modification, High steric selectivity |
| Pressure stability | : | 600 bar |
| Separation principle | : | Reversed phase (RP) |
| Temperature stability | : | 60 ° C |
| L x Ø internal (column) | : | 125 x 4.6 mm |
| Recommended application(s) | : | Separation of positional and structural isomers Planar/non-planar molecules Steroids Suitable for LC-MS (o,p,m-)Substituted aromatics Fat-soluble vitamins Exceptional steric selectivity |
| Specific surface according to BET | : | 340 m²/g |
| Interactions / retention mechanism | : | steric and hydrophobic |