HPLC column NUCLEODUR ® PFP, 1.8 µm, 100 mm, 4 mm
Order number: 34YE.1
Part number: AC100007336
£ 788.54*
*Prices plus VAT plus shipping costs£ 946.25*
*incl. VAT, plus shipping costsPrice Breakdown
1
6
24
Crafted to support technical production environments, the Hplc Column Nucleodur ® PFP, 1.8 μm, 100 mm, 4 mm, falls under the category of Separation columns for HPLC. This UHPLC column features a Pentafluorophenylpropyl (PFP) modification on high purity NUCLEODUR ® silica gel, offering an alternative selectivity compared to traditional C 18 modifications. Its four retention mechanisms—polar interactions (H bonds), dipole-dipole interactions, π-π interactions, and hydrophobic interactions—make it suitable for LC/MS applications due to its low bleeding characteristics. The column's specifications include a particle size of 1.8 μm, a temperature stability of 60 °C, and a pressure stability of 900 bar. Re
- Category: Separation columns for HPLC
- Eluent in column: Acetonitrile - Water
- Specific surface according to BET: 340 m²/g
- Interactions / retention mechanism: polar (H-bond), dipole-dipole, π-π and hydrophobic
- USP listing: L43
- Temperature stability: 60 ° C
- Separation principle: Reversed phase (RP)
- Pressure stability: 900 bar
- Endcapped: yes
- Column type: UHPLC column
- Pore volume: 0.9 ml/g
- pH stability: 1,0-9,0
- Pore size: 110 Å
- Surface chemistry: Pentafluorophenylpropyl (PFP) modification
- L x Ø internal (column): 100 x 4 mm
- Phase: PFP
- Column volume: 1.25 ml
- Particle type: Fully porous particles (FPP)
- Particle size: 1.8 µm
- Recommended application(s): Antibiotics Aromatic and unsaturated compounds Basic compounds Suitable for LC-MS Halogenated compounds Isomers Pharmaceutical products Phenols Especially for polar compounds
- Column shape: Analytical separation column
| Name | Value | |
|---|---|---|
| Phase | : | PFP |
| Endcapped | : | yes |
| Pore size | : | 110 Å |
| Column type | : | UHPLC column |
| Pore volume | : | 0.9 ml/g |
| USP listing | : | L43 |
| Column shape | : | Analytical separation column |
| pH stability | : | 1,0-9,0 |
| Column volume | : | 1.25 ml |
| Particle size | : | 1.8 µm |
| Particle type | : | Fully porous particles (FPP) |
| Eluent in column | : | Acetonitrile - Water |
| Surface chemistry | : | Pentafluorophenylpropyl (PFP) modification |
| Pressure stability | : | 900 bar |
| Separation principle | : | Reversed phase (RP) |
| Temperature stability | : | 60 ° C |
| L x Ø internal (column) | : | 100 x 4 mm |
| Recommended application(s) | : | Antibiotics Aromatic and unsaturated compounds Basic compounds Suitable for LC-MS Halogenated compounds Isomers Pharmaceutical products Phenols Especially for polar compounds |
| Specific surface according to BET | : | 340 m²/g |
| Interactions / retention mechanism | : | polar (H-bond), dipole-dipole, π-π and hydrophobic |