HPLC column NUCLEODUR ® Phenyl-Hexyl, 3 µm, 250 mm, 4 mm
Order number: 34NK.1
Part number: AC100008142
£ 899.78*
*Prices plus VAT plus shipping costs£ 1079.74*
*incl. VAT, plus shipping costsPrice Breakdown
1
6
24
Designed for professional use, the Hplc Column Nucleodur ® Phenyl-Hexyl, 3 μm, 250 mm, 4 mm features a reversed phase (RP) separation principle that utilizes both π-π interactions and hydrophobic interactions for effective separation. With a particle size of 3 μm, fully porous particles (FPP), and a pore size of 110 Å, it offers a specific surface area of 340 m²/g and a pore volume of 0.9 ml/g. This analytical separation column, made of stainless steel, has a length of 250 mm and an inner diameter of 4 mm, providing a total column volume of 3.15 ml. It is suitable for a wide range of applications including antibiotics, aromatic and unsaturated compounds, pharmaceut
- Category: Separation columns for HPLC
- Recommended application(s): Antibiotics Aromatic and unsaturated compounds Suitable for LC-MS Pharmaceutical products Especially for polar compounds Steroids
- Particle size: 3 µm
- Column type: HPLC column
- pH stability: 1,0-10,0
- Eluent in column: Acetonitrile - Water
- Endcapped: yes
- USP listing: L11
- Particle type: Fully porous particles (FPP)
- Surface chemistry: Phenylhexyl modification
- Pressure stability: 600 bar
- Pore volume: 0.9 ml/g
- Column volume: 3.15 ml
- Pore size: 110 Å
- Phase: Phenyl-Hexyl
- Separation principle: Reversed phase (RP)
- Specific surface according to BET: 340 m²/g
- Interactions / retention mechanism: π-π and hydrophobic
- Temperature stability: 60 ° C
- Column shape: Analytical separation column
- L x Ø internal (column): 250 x 4 mm
| Name | Value | |
|---|---|---|
| Phase | : | Phenyl-Hexyl |
| Endcapped | : | yes |
| Pore size | : | 110 Å |
| Column type | : | HPLC column |
| Pore volume | : | 0.9 ml/g |
| USP listing | : | L11 |
| Column shape | : | Analytical separation column |
| pH stability | : | 1,0-10,0 |
| Column volume | : | 3.15 ml |
| Particle size | : | 3 µm |
| Particle type | : | Fully porous particles (FPP) |
| Eluent in column | : | Acetonitrile - Water |
| Surface chemistry | : | Phenylhexyl modification |
| Pressure stability | : | 600 bar |
| Separation principle | : | Reversed phase (RP) |
| Temperature stability | : | 60 ° C |
| L x Ø internal (column) | : | 250 x 4 mm |
| Recommended application(s) | : | Antibiotics Aromatic and unsaturated compounds Suitable for LC-MS Pharmaceutical products Especially for polar compounds Steroids |
| Specific surface according to BET | : | 340 m²/g |
| Interactions / retention mechanism | : | π-π and hydrophobic |