HPLC column NUCLEODUR ® Phenyl-Hexyl, 1.8 µm, 50 mm, 4.6 mm
Order number: 34L9.1
Part number: AC100008311
£ 744.98*
*Prices plus VAT plus shipping costs£ 893.98*
*incl. VAT, plus shipping costsPrice Breakdown
1
6
24
Designed to integrate seamlessly into laboratory operations, the Hplc Column Nucleodur ® Phenyl-Hexyl, 1.8 μm, 50 Mm, 4.6 Mm offers exceptional versatility as a UHPLC column. Featuring a Phenyl-Hexyl phase, this reversed phase column provides an alternative selectivity compared to traditional C18 modifications, making it ideal for separating aromatic and unsaturated compounds, antibiotics, pharmaceutical products, steroids, and even polar compounds. With a particle size of 1.8 μm, this fully porous particle (FPP) column boasts a specific surface area of 340 m²/g, ensuring optimal performance under pressure up to 900 bar. Additionally, its temperature stability of 60°C and pH range compatibility of 1.0
- Category: Separation columns for HPLC
- L x Ø internal (column): 50 x 4.6 mm
- Eluent in column: Acetonitrile - Water
- Column volume: 0.83 ml
- Endcapped: yes
- Specific surface according to BET: 340 m²/g
- USP listing: L11
- Particle type: Fully porous particles (FPP)
- Temperature stability: 60 ° C
- Column shape: Analytical separation column
- Separation principle: Reversed phase (RP)
- Recommended application(s): Antibiotics Aromatic and unsaturated compounds Suitable for LC-MS Pharmaceutical products Especially for polar compounds Steroids
- Pore size: 110 Å
- pH stability: 1,0-10,0
- Column type: UHPLC column
- Particle size: 1.8 µm
- Pressure stability: 900 bar
- Interactions / retention mechanism: π-π and hydrophobic
- Pore volume: 0.9 ml/g
- Surface chemistry: Phenylhexyl modification
- Phase: Phenyl-Hexyl
| Name | Value | |
|---|---|---|
| Phase | : | Phenyl-Hexyl |
| Endcapped | : | yes |
| Pore size | : | 110 Å |
| Column type | : | UHPLC column |
| Pore volume | : | 0.9 ml/g |
| USP listing | : | L11 |
| Column shape | : | Analytical separation column |
| pH stability | : | 1,0-10,0 |
| Column volume | : | 0.83 ml |
| Particle size | : | 1.8 µm |
| Particle type | : | Fully porous particles (FPP) |
| Eluent in column | : | Acetonitrile - Water |
| Surface chemistry | : | Phenylhexyl modification |
| Pressure stability | : | 900 bar |
| Separation principle | : | Reversed phase (RP) |
| Temperature stability | : | 60 ° C |
| L x Ø internal (column) | : | 50 x 4.6 mm |
| Recommended application(s) | : | Antibiotics Aromatic and unsaturated compounds Suitable for LC-MS Pharmaceutical products Especially for polar compounds Steroids |
| Specific surface according to BET | : | 340 m²/g |
| Interactions / retention mechanism | : | π-π and hydrophobic |