HPLC column NUCLEODUR ® C 18 Isis, 1.8 µm, 30 mm, 3 mm
Order number: 345T.1
Part number: AC100008593
£ 686.93*
*Prices plus VAT plus shipping costs£ 824.32*
*incl. VAT, plus shipping costsPrice Breakdown
1
6
24
Tailored for precision-driven chemical tasks, the Hplc Column Nucleodur ® C 18 Isis, 1.8 μm, 30 Mm, 3 Mm offers exceptional steric selectivity as a UHPLC column with a nonpolar crosslinked polymeric octadecyl (C 18 , ODS) modification. It boasts a specific surface area of 340 m²/g, allowing it to separate positional and structural isomers, planar/non-planar molecules, steroids, fat-soluble vitamins, and even ( o , p , m -) substituted aromatics. With a recommended operating temperature of up to 60 ° C and pressure stability of 900 bar, this column ensures reliable performance under various conditions. Its particle size of 1.8 μm, coupled with
- Category: Separation columns for HPLC
- Separation principle: Reversed phase (RP)
- Specific surface according to BET: 340 m²/g
- Particle size: 1.8 µm
- Eluent in column: Acetonitrile - Water
- Pore volume: 0.9 ml/g
- Column volume: 0.2 ml
- Temperature stability: 60 ° C
- Interactions / retention mechanism: steric and hydrophobic
- Recommended application(s): Separation of positional and structural isomers Planar/non-planar molecules Steroids Suitable for LC-MS (o,p,m-)Substituted aromatics Fat-soluble vitamins Exceptional steric selectivity
- pH stability: 1,0-10,0
- L x Ø internal (column): 30 x 3 mm
- Column shape: Analytical separation column
- Pore size: 110 Å
- Particle type: Fully porous particles (FPP)
- Surface chemistry: Nonpolar crosslinked polymeric octadecyl (C 18 , ODS) modification, High steric selectivity
- Phase: C 18 Isis
- Pressure stability: 900 bar
- USP listing: L1
- Column type: UHPLC column
- Endcapped: yes
| Name | Value | |
|---|---|---|
| Phase | : | C 18 Isis |
| Endcapped | : | yes |
| Pore size | : | 110 Å |
| Column type | : | UHPLC column |
| Pore volume | : | 0.9 ml/g |
| USP listing | : | L1 |
| Column shape | : | Analytical separation column |
| pH stability | : | 1,0-10,0 |
| Column volume | : | 0.2 ml |
| Particle size | : | 1.8 µm |
| Particle type | : | Fully porous particles (FPP) |
| Eluent in column | : | Acetonitrile - Water |
| Surface chemistry | : | Nonpolar crosslinked polymeric octadecyl (C 18 , ODS) modification, High steric selectivity |
| Pressure stability | : | 900 bar |
| Separation principle | : | Reversed phase (RP) |
| Temperature stability | : | 60 ° C |
| L x Ø internal (column) | : | 30 x 3 mm |
| Recommended application(s) | : | Separation of positional and structural isomers Planar/non-planar molecules Steroids Suitable for LC-MS (o,p,m-)Substituted aromatics Fat-soluble vitamins Exceptional steric selectivity |
| Specific surface according to BET | : | 340 m²/g |
| Interactions / retention mechanism | : | steric and hydrophobic |