HPLC column NUCLEODUR ® C 4 ec, 250 mm, 2 mm
Order number: 35P2.1
Part number: AC100008650
£ 556.34*
*Prices plus VAT plus shipping costs£ 667.61*
*incl. VAT, plus shipping costsPrice Breakdown
1
6
24
Engineered to maintain reliability in process-driven workflows, the Hplc Column Nucleodur® C 4 Ec, 250 mm, 2 mm offers exceptional performance for separating biomolecules such as proteins and peptides. This reversed-phase analytical separation column features a medium density monomeric butyl (C 4 ) wide-pore modification, ensuring optimal interaction and retention mechanisms through hydrophobic van der Waals interactions and some residual silanol interactions. With a particle size of 5 μm, it delivers a specific surface area of 100 m²/g, providing efficient separation capabilities. Its temperature stability up to 60°C and pressure resistance up to 450 bar make this column suitable for various lab conditions.
- Category: Separation columns for HPLC
- Phase: C 4 ec
- Pressure stability: 450 bar
- Similar phases: Jupiter ® C 4 ACE ® C 4
- Column shape: Analytical separation column
- Particle size: 5 µm
- L x Ø internal (column): 250 x 2 mm
- Surface chemistry: Medium density monomeric butyl (C 4 ) wide-pore modification
- USP listing: L26
- Temperature stability: 60 ° C
- Particle type: Fully porous particles (FPP)
- Interactions / retention mechanism: hydrophobic (van der Waals interactions), some residual silanol interactions
- Separation principle: Reversed phase (RP)
- Recommended application(s): Biomolecular macromolecules, like proteins and peptides
- Eluent in column: Acetonitrile - Water
- Specific surface according to BET: 100 m²/g
- pH stability: 1,0-9,0
- Pore size: 300 Å
- Endcapped: yes
- Column volume: 0.8 ml
- Pore volume: 0.9 ml/g
- Column type: HPLC column
| Name | Value | |
|---|---|---|
| Phase | : | C 4 ec |
| Endcapped | : | yes |
| Pore size | : | 300 Å |
| Column type | : | HPLC column |
| Pore volume | : | 0.9 ml/g |
| USP listing | : | L26 |
| Column shape | : | Analytical separation column |
| pH stability | : | 1,0-9,0 |
| Column volume | : | 0.8 ml |
| Particle size | : | 5 µm |
| Particle type | : | Fully porous particles (FPP) |
| Similar phases | : | Jupiter ® C 4 ACE ® C 4 |
| Eluent in column | : | Acetonitrile - Water |
| Surface chemistry | : | Medium density monomeric butyl (C 4 ) wide-pore modification |
| Pressure stability | : | 450 bar |
| Separation principle | : | Reversed phase (RP) |
| Temperature stability | : | 60 ° C |
| L x Ø internal (column) | : | 250 x 2 mm |
| Recommended application(s) | : | Biomolecular macromolecules, like proteins and peptides |
| Specific surface according to BET | : | 100 m²/g |
| Interactions / retention mechanism | : | hydrophobic (van der Waals interactions), some residual silanol interactions |