HPLC column NUCLEODUR ® C 18 HTec, 5 µm, 100 mm, 2 mm
Order number: 35AK.1
Part number: AC100008689
£ 619.20*
*Prices plus VAT plus shipping costs£ 743.04*
*incl. VAT, plus shipping costsPrice Breakdown
1
6
24
Formulated to support synthetic operations, the Hplc Column Nucleodur ® C 18 Htec, 5 μm, 100 Mm, 2 Mm is a valuable addition to any lab working with separation columns for HPLC. This analytical separation column features fully porous particles (FPP) and a reversed phase (RP) separation principle, making it suitable for a wide range of applications including aldehydes, fat-soluble vitamins, and phenolic compounds. With a specific surface area of 340 m²/g and a pressure stability of 600 bar, this column offers high loadability and excellent stability, making it an ideal choice for up-scaling to preparative scale. Additionally, its temperature stability of 60°C and compatibility with both LC-MS and extreme pH values (1-11) make it vers
- Category: Separation columns for HPLC
- pH stability: 1,0-11,0
- Pore volume: 0.9 ml/g
- Particle size: 5 µm
- Surface chemistry: Base deactivated (BDS), High density octadecyl (C 18 , ODS) modification
- Separation principle: Reversed phase (RP)
- Recommended application(s): Aldehydes Applications at extreme pH values (1-11) Alkaline, neutral and acidic pharmaceuticals Derivatised amino acids Fat-soluble vitamins Suitable for LC-MS High loading capacity Ketones Pesticides Phenolic compounds
- Specific surface according to BET: 340 m²/g
- Endcapped: yes
- USP listing: L1
- Interactions / retention mechanism: hydrophobic (van der Waals)
- Pressure stability: 600 bar
- Column shape: Analytical separation column
- Particle type: Fully porous particles (FPP)
- Pore size: 110 Å
- Column type: HPLC column
- Column volume: 0.3 ml
- Phase: C 18 HTec
- Temperature stability: 60 ° C
- L x Ø internal (column): 100 x 2 mm
- Eluent in column: Acetonitrile - Water
| Name | Value | |
|---|---|---|
| Phase | : | C 18 HTec |
| Endcapped | : | yes |
| Pore size | : | 110 Å |
| Column type | : | HPLC column |
| Pore volume | : | 0.9 ml/g |
| USP listing | : | L1 |
| Column shape | : | Analytical separation column |
| pH stability | : | 1,0-11,0 |
| Column volume | : | 0.3 ml |
| Particle size | : | 5 µm |
| Particle type | : | Fully porous particles (FPP) |
| Eluent in column | : | Acetonitrile - Water |
| Surface chemistry | : | Base deactivated (BDS), High density octadecyl (C 18 , ODS) modification |
| Pressure stability | : | 600 bar |
| Separation principle | : | Reversed phase (RP) |
| Temperature stability | : | 60 ° C |
| L x Ø internal (column) | : | 100 x 2 mm |
| Recommended application(s) | : | Aldehydes Applications at extreme pH values (1-11) Alkaline, neutral and acidic pharmaceuticals Derivatised amino acids Fat-soluble vitamins Suitable for LC-MS High loading capacity Ketones Pesticides Phenolic compounds |
| Specific surface according to BET | : | 340 m²/g |
| Interactions / retention mechanism | : | hydrophobic (van der Waals) |
