HPLC column NUCLEODUR ® PolarTec, 1.8 µm, 100 mm, 4 mm
Order number: 34EY.1
Part number: AC100008702
£ 788.54*
*Prices plus VAT plus shipping costs£ 946.25*
*incl. VAT, plus shipping costsPrice Breakdown
1
6
24
Tailored for precision-driven chemical tasks, the Hplc Column Nucleodur ® Polartec, featuring a particle size of 1.8 μm and a length of 100 mm, delivers exceptional performance in separating amino acids, basic pharmaceuticals, nitrogen-containing compounds, organic acids, pesticides, phenols, water-soluble vitamins, and other polar compounds. With its unique combination of a polar group embedded in a hydrophobic C 18 modification, this UHPLC column exhibits both steric and enhanced polar selectivity, making it suitable for 100% aqueous eluents and even LC/MS applications. Its specific surface area of 340 m²/g ensures optimal interaction and retention mechanisms via hydrophobic and polar interactions, while maintaining low bleeding characteristics. The column'
- Category: Separation columns for HPLC
- Separation principle: Reversed phase (RP)
- Pressure stability: 900 bar
- USP listing: L1 L60
- Endcapped: yes
- Particle type: Fully porous particles (FPP)
- Surface chemistry: Octadecyl phase (C 18 , ODS) modification, with embedded polar group (PEG)
- Phase: PolarTec
- Particle size: 1.8 µm
- Column shape: Analytical separation column
- Specific surface according to BET: 340 m²/g
- Pore volume: 0.9 ml/g
- pH stability: 1,0-9,0
- Temperature stability: 60 ° C
- Pore size: 110 Å
- Interactions / retention mechanism: hydrophobic and polar (H bonds)
- Column type: UHPLC column
- Eluent in column: Acetonitrile - Water
- L x Ø internal (column): 100 x 4 mm
- Column volume: 1.25 ml
- Recommended application(s): Amino acids Basic pharmaceuticals Especially for polar compounds Nitrogen containing compounds Organic acids Pesticides Phenols Suitable for 100 % aqueous eluents Suitable for LC-MS Water-soluble vitamins
| Name | Value | |
|---|---|---|
| Phase | : | PolarTec |
| Endcapped | : | yes |
| Pore size | : | 110 Å |
| Column type | : | UHPLC column |
| Pore volume | : | 0.9 ml/g |
| USP listing | : | L1 L60 |
| Column shape | : | Analytical separation column |
| pH stability | : | 1,0-9,0 |
| Column volume | : | 1.25 ml |
| Particle size | : | 1.8 µm |
| Particle type | : | Fully porous particles (FPP) |
| Eluent in column | : | Acetonitrile - Water |
| Surface chemistry | : | Octadecyl phase (C 18 , ODS) modification, with embedded polar group (PEG) |
| Pressure stability | : | 900 bar |
| Separation principle | : | Reversed phase (RP) |
| Temperature stability | : | 60 ° C |
| L x Ø internal (column) | : | 100 x 4 mm |
| Recommended application(s) | : | Amino acids Basic pharmaceuticals Especially for polar compounds Nitrogen containing compounds Organic acids Pesticides Phenols Suitable for 100 % aqueous eluents Suitable for LC-MS Water-soluble vitamins |
| Specific surface according to BET | : | 340 m²/g |
| Interactions / retention mechanism | : | hydrophobic and polar (H bonds) |