HPLC column NUCLEODUR ® π 2 , 5 µm, 250 mm, 3 mm
Order number: 34XX.1
Part number: AC100008704
£ 720.81*
*Prices plus VAT plus shipping costs£ 864.97*
*incl. VAT, plus shipping costsPrice Breakdown
1
6
24
Designed with efficiency in synthetic processes in mind, this Separation column for HPLC, specifically the HPLC column NUCLEODUR ® Π 2, boasts a 5 μm particle size and a 250 mm length, providing an optimal balance between resolution and speed. Its unique biphenylpropyl modification offers a hydrophobic phase with alternative selectivity compared to traditional C18 modifications, making it particularly suitable for separating aromatic and unsaturated substances such as antibiotics, pharmaceutical products, steroids, and other polar compounds. With a pressure stability of up to 600 bar and temperature stability at 60°C, this column ensures robust performance even under challenging conditions. The column's pore size of 110 Å and pore volume of 0.9 ml/g, combined with its specific surface area of 340
- Category: Separation columns for HPLC
- Specific surface according to BET: 340 m²/g
- Eluent in column: Acetonitrile - Water
- Surface chemistry: Biphenylpropyl modification
- Column shape: Analytical separation column
- Pore volume: 0.9 ml/g
- Recommended application(s): Antibiotics Particularly aromatic and unsaturated compounds Pharmaceutical products Especially for polar compounds Steroids
- Particle size: 5 µm
- Pore size: 110 Å
- Particle type: Fully porous particles (FPP)
- L x Ø internal (column): 250 x 3 mm
- Temperature stability: 60 ° C
- Separation principle: Reversed phase (RP)
- Pressure stability: 600 bar
- Column volume: 1.75 ml
- Endcapped: yes
- pH stability: 3,0-10,0
- Column type: HPLC column
- Interactions / retention mechanism: π-π and hydrophobic
- USP listing: L11
- Phase: π 2
| Name | Value | |
|---|---|---|
| Phase | : | π 2 |
| Endcapped | : | yes |
| Pore size | : | 110 Å |
| Column type | : | HPLC column |
| Pore volume | : | 0.9 ml/g |
| USP listing | : | L11 |
| Column shape | : | Analytical separation column |
| pH stability | : | 3,0-10,0 |
| Column volume | : | 1.75 ml |
| Particle size | : | 5 µm |
| Particle type | : | Fully porous particles (FPP) |
| Eluent in column | : | Acetonitrile - Water |
| Surface chemistry | : | Biphenylpropyl modification |
| Pressure stability | : | 600 bar |
| Separation principle | : | Reversed phase (RP) |
| Temperature stability | : | 60 ° C |
| L x Ø internal (column) | : | 250 x 3 mm |
| Recommended application(s) | : | Antibiotics Particularly aromatic and unsaturated compounds Pharmaceutical products Especially for polar compounds Steroids |
| Specific surface according to BET | : | 340 m²/g |
| Interactions / retention mechanism | : | π-π and hydrophobic |