HPLC column NUCLEODUR ® π 2 , 5 µm, 250 mm, 2 mm
Order number: 34XT.1
Part number: AC100008871
£ 725.63*
*Prices without VAT and shipping costs£ 870.76*
*incl. VAT, plus shipping costsPrice Breakdown
1
6
24
Prepared for use in regulated laboratory conditions, the HPLC Column Nucleodur ® Π 2, 5 μm, 250 mm, 2 mm is designed for the separation of antibiotics, particularly aromatic and unsaturated compounds, pharmaceutical products, especially for polar compounds, and steroids. With its biphenylpropyl modification and reversed phase (RP) separation principle, this column exhibits exceptional performance under highly aqueous conditions due to its π-π and hydrophobic interaction capabilities. Featuring a particle size of 5 μm, pore size of 110 Å, and specific surface area of 340 m²/g, it offers a pressure stability of up to 600 bar and temperature stability of 60 °C. This analytical separation column comes with a pH stability range of
- Category: Separation columns for HPLC
- Interactions / retention mechanism: π-π and hydrophobic
- pH stability: 3,0-10,0
- Pressure stability: 600 bar
- Application Database (Macherey-Nagel): HPLC
- Column shape: Analytical separation column
- Particle size: 5 µm
- Column volume: 0.8 ml
- Column type: HPLC column
- Pore volume: 0.9 ml/g
- Endcapped: yes
- Specific surface according to BET: 340 m²/g
- Pore size: 110 Å
- Separation principle: Reversed phase (RP)
- Eluent in column: Acetonitrile - Water
- Particle type: Fully porous particles (FPP)
- Phase: π 2
- L x Ø internal (column): 250 x 2 mm
- Surface chemistry: Biphenylpropyl modification
- Recommended application(s): Antibiotics Particularly aromatic and unsaturated compounds Pharmaceutical products Especially for polar compounds Steroids
- Temperature stability: 60 ° C
- USP listing: L11
| Name | Value | |
|---|---|---|
| Phase | : | π 2 |
| Endcapped | : | yes |
| Pore size | : | 110 Å |
| Column type | : | HPLC column |
| Pore volume | : | 0.9 ml/g |
| USP listing | : | L11 |
| Column shape | : | Analytical separation column |
| pH stability | : | 3,0-10,0 |
| Column volume | : | 0.8 ml |
| Particle size | : | 5 µm |
| Particle type | : | Fully porous particles (FPP) |
| Eluent in column | : | Acetonitrile - Water |
| Surface chemistry | : | Biphenylpropyl modification |
| Pressure stability | : | 600 bar |
| Separation principle | : | Reversed phase (RP) |
| Temperature stability | : | 60 ° C |
| L x Ø internal (column) | : | 250 x 2 mm |
| Recommended application(s) | : | Antibiotics Particularly aromatic and unsaturated compounds Pharmaceutical products Especially for polar compounds Steroids |
| Specific surface according to BET | : | 340 m²/g |
| Interactions / retention mechanism | : | π-π and hydrophobic |
| Application Database (Macherey-Nagel) | : | HPLC |