HPLC column NUCLEODUR ® C 18 Isis, 1.8 µm, 50 mm, 2 mm
Order number: 3460.1
Part number: AC100009000
£ 686.93*
*Prices without VAT and shipping costs£ 824.32*
*incl. VAT, plus shipping costsPrice Breakdown
1
6
24
Structured to assist in consistent experimental procedures, the Hplc Column Nucleodur ® C 18 Isis, 1.8 μm, 50 mm, 2 mm offers exceptional steric selectivity for the separation of positional and structural isomers, planar/non-planar molecules, steroids, and fat-soluble vitamins. Its nonpolar crosslinked polymeric octadecyl (C 18 , ODS) modification provides high steric selectivity, making it suitable for LC-MS applications, particularly for (o,p,m-)substituted aromatics. With a pressure stability of 900 bar and temperature stability up to 60 °C, this UHPLC column ensures reliable performance under various conditions. The specific surface area of 340 m²/g and pore volume of 0.9 ml
- Category: Separation columns for HPLC
- Application Database (Macherey-Nagel): HPLC
- Separation principle: Reversed phase (RP)
- Recommended application(s): Separation of positional and structural isomers Planar/non-planar molecules Steroids Suitable for LC-MS (o,p,m-)Substituted aromatics Fat-soluble vitamins Exceptional steric selectivity
- Pressure stability: 900 bar
- Pore size: 110 Å
- Pore volume: 0.9 ml/g
- Particle size: 1.8 µm
- Phase: C 18 Isis
- Eluent in column: Acetonitrile - Water
- Column type: UHPLC column
- Specific surface according to BET: 340 m²/g
- Interactions / retention mechanism: steric and hydrophobic
- Particle type: Fully porous particles (FPP)
- Endcapped: yes
- Temperature stability: 60 ° C
- Surface chemistry: Nonpolar crosslinked polymeric octadecyl (C 18 , ODS) modification, High steric selectivity
- Column volume: 0.15 ml
- L x Ø internal (column): 50 x 2 mm
- USP listing: L1
- Column shape: Analytical separation column
- pH stability: 1,0-10,0
| Name | Value | |
|---|---|---|
| Phase | : | C 18 Isis |
| Endcapped | : | yes |
| Pore size | : | 110 Å |
| Column type | : | UHPLC column |
| Pore volume | : | 0.9 ml/g |
| USP listing | : | L1 |
| Column shape | : | Analytical separation column |
| pH stability | : | 1,0-10,0 |
| Column volume | : | 0.15 ml |
| Particle size | : | 1.8 µm |
| Particle type | : | Fully porous particles (FPP) |
| Eluent in column | : | Acetonitrile - Water |
| Surface chemistry | : | Nonpolar crosslinked polymeric octadecyl (C 18 , ODS) modification, High steric selectivity |
| Pressure stability | : | 900 bar |
| Separation principle | : | Reversed phase (RP) |
| Temperature stability | : | 60 ° C |
| L x Ø internal (column) | : | 50 x 2 mm |
| Recommended application(s) | : | Separation of positional and structural isomers Planar/non-planar molecules Steroids Suitable for LC-MS (o,p,m-)Substituted aromatics Fat-soluble vitamins Exceptional steric selectivity |
| Specific surface according to BET | : | 340 m²/g |
| Interactions / retention mechanism | : | steric and hydrophobic |
| Application Database (Macherey-Nagel) | : | HPLC |