Produced for stability across temperature-sensitive applications, the Penetration Infrared Thermometer TLC Series TLC 750I-V2 falls under the category of calibrated, gauged thermometers. This versatile instrument offers both contact and non-contact temperature measurements, making it ideal for incoming goods inspection, transportation, storage, and monitoring of the cold chain. Its factory calibration certificate verifies its accuracy at test points of -18 and 0 °C. Featuring an illuminated display for easy readability in low light conditions, this thermometer also includes a two-point laser mark for precise indication of the measurement spot. The penetration probe, which conforms to HACCP and DIN EN 13485 standards, is dust and waterproof according to IP 65. Equipped with a simplified one-button operation system, the TLC 750I-V
- Category: Thermometers (calibrated, gauged)
- Penetration probe measuring range: -50 to +250 °C
- Type: TLC 750i-V2
- Measurement spot marking: yes
- Weight: 140 g
- Power supply: 2 x 1.5 V AAA batteries
- Measuring cycle: Infrared: 0.7 s, penetration probe: 1 s
- L x W x H: 170 x 44 x 23 mm
- Temperature resolution: 0.1 °C
- Infrared measuring range: -50 to +250 °C
- Temperature accuracy: infrared: ±4 °C (-50 to -30 °C) ±2.5 °C (-30 to -18 °C) ±1.5 °C (-18 to 0 °C) ±1.0 °C (0 to +65 °C) ±2.0 °C (+65 to +250 °C) penetration probe: ±0.5°C (-30 to +99 °C) ±1% of the measured value (outside)
- Parameters: temperature
- Measuring distance : measuring spot ratio: 8:1
- Emissivity: 0,95
| Name | Value | |
|---|---|---|
| Type | : | TLC 750i-V2 |
| Weight | : | 140 g |
| L x W x H | : | 170 x 44 x 23 mm |
| Emissivity | : | 0,95 |
| Parameters | : | temperature |
| Power supply | : | 2 x 1.5 V AAA batteries |
| Measuring cycle | : | Infrared: 0.7 s, penetration probe: 1 s |
| Temperature accuracy | : | infrared: ±4 °C (-50 to -30 °C) ±2.5 °C (-30 to -18 °C) ±1.5 °C (-18 to 0 °C) ±1.0 °C (0 to +65 °C) ±2.0 °C (+65 to +250 °C) penetration probe: ±0.5°C (-30 to +99 °C) ±1% of the measured value (outside) |
| Temperature resolution | : | 0.1 °C |
| Infrared measuring range | : | -50 to +250 °C |
| Measurement spot marking | : | yes |
| Penetration probe measuring range | : | -50 to +250 °C |
| Measuring distance : measuring spot ratio | : | 8:1 |