Deliver to United Kingdom
0
Products Found: 28
Showing Results For: 90 mm plates (ROTI®Plate90)

90 mm plates (ROTI®Plate90)



New Items
New
1LE1.1, Carl

1LE1.1, Carl

Sterile Sterile ready-to-use culture media plates for microbiological analysis. Diameter 90 mm Surface 63,6 cm 2 Ready-to-use and sterile Easy to use, reliable detection and simple evaluation Well applicable for microbiological analysis of samples With detailed instructions for use ROTI ® Plate90 are prepared culture media plates with a diameter of 90 mm. They are thus adapted to the size of membrane filters for assaying of low-germ fluids by membrane filtration method. They are also applicable for the microbiological analysis of samples in general. The germs of expected low-germ liquid samples are concentrated by membrane filtration. Afterwards, the membrane is placed on top of the medium and incubated. Using a membrane with a grid helps counting the resulting colonies. Our products are tested and approved exclusively for research and development. Samples which are expected to have a higher microbiological burden are prepared in a serial dilution. Afterwards, every dilution step is plated and incubated. The number of grown colonies is noted as result. ROTI ® Plate90 Endo ISO 11133, ready-to-use, sterile, for microbiology Endo Agar is used for the differentiation of lactose-fermenting and non-lactose-fermenting intestinal bacteria, specifically to confirm tests when coliforms are suspected. The production of acid and aldehyde by lactose fermenting organisms such as Escherichia coli , results in the characteristic red colouration of the colony and the surrounding medium, along with a brilliant golden metallic sheen. Non-lactose fermenting bacteria result in colourless and transparent colonies.

Product Detail
New
1K26.1, Carl

1K26.1, Carl

Sterile Sterile ready-to-use culture media plates for microbiological analysis. Diameter 90 mm Surface 63,6 cm 2 Ready-to-use and sterile Easy to use, reliable detection and simple evaluation Well applicable for microbiological analysis of samples With detailed instructions for use ROTI ® Plate90 are prepared culture media plates with a diameter of 90 mm. They are thus adapted to the size of membrane filters for assaying of low-germ fluids by membrane filtration method. They are also applicable for the microbiological analysis of samples in general. The germs of expected low-germ liquid samples are concentrated by membrane filtration. Afterwards, the membrane is placed on top of the medium and incubated. Using a membrane with a grid helps counting the resulting colonies. Our products are tested and approved exclusively for research and development. Samples which are expected to have a higher microbiological burden are prepared in a serial dilution. Afterwards, every dilution step is plated and incubated. The number of grown colonies is noted as result. ROTI ® Plate90 MRS ISO 11133, ready-to-use, sterile, for microbiology MRS Agar was developed by deMan, Rogosa and Sharpe to grow luxuriantly all strains of Lactobacilli especially the fastidious, slower-growing types such as L. brevis and L. fermenti . The medium is apt for the growth of lactic acid bacteria, including Lactobacillus , Streptococcus , Pediococcus and Leuconostoc . Ammonium citrate at a low pH inhibits most microorganisms, including other Streptococci and molds. It allows for the growth of Lactobacillus , but limits swarming in general. Not a medical device / Not an IVD product

Product Detail
New
1K21.1, Carl

1K21.1, Carl

Sterile Sterile ready-to-use culture media plates for microbiological analysis. Diameter 90 mm Surface 63,6 cm 2 Ready-to-use and sterile Easy to use, reliable detection and simple evaluation Well applicable for microbiological analysis of samples With detailed instructions for use ROTI ® Plate90 are prepared culture media plates with a diameter of 90 mm. They are thus adapted to the size of membrane filters for assaying of low-germ fluids by membrane filtration method. They are also applicable for the microbiological analysis of samples in general. The germs of expected low-germ liquid samples are concentrated by membrane filtration. Afterwards, the membrane is placed on top of the medium and incubated. Using a membrane with a grid helps counting the resulting colonies. Our products are tested and approved exclusively for research and development. Samples which are expected to have a higher microbiological burden are prepared in a serial dilution. Afterwards, every dilution step is plated and incubated. The number of grown colonies is noted as result. ROTI ® Plate90 TSA 4N acc. to Ph. Eur./USP, ISO 11133, ready-to-use, sterile, for microbiology Tryptone soy agar (TSA) is recommended by the Ph. Eur. and USP for testing products under investigation for the presence of bacteria by the membrane filter method, and for counting bacteria on agar plates or by the dilution method (MPN method). As this medium contains two peptones obtained by enzymatic hydrolysis of casein and soy protein, it supports a wide range of microorganisms, including fastidious aerobic and anaerobic organisms. The included disinhibitors lecithin, polysorbate 80 (Tween ® 80), sodium thiosulphate and histidine are also called neutralisers. Disinhibitors serve to neutralise residues of disinfectants and preservatives and ensure bacterial growth. The triple packaging allows the use of the plates in the cleanroom. Not a medical device / Not an IVD product

Product Detail
New
37E0.1, Carl

37E0.1, Carl

Sterile Sterile ready-to-use culture media plates for microbiological analysis in isolators and cleanrooms. Diameter 90 mm Surface 63,6 cm 2 Ready-to-use and sterile Easy to use, reliable detection and simple evaluation Well applicable for microbiological analysis of samples With detailed instructions for use Triple packaged and Gamma irradiated Suitable for usage in isolators and cleanrooms ROTI ® Plate ICR are 90 mm ready-to-use nutrient trays that are triple-packed and gamma-irradiated, which enables them to be used in cleanrooms and isolators. With irradiation indicator and barcode labeling. ROTI ® Plate ICR TSA TLHTh acc. to Ph. Eur./USP, ISO 11133, ready-to-use, sterile, for microbiology The TSA agar with enteric inhibitors is suitable according to Ph. Eur. and USP for determination of the total bacterial count after disinfection. Triple packaging and gamma irradiation enable the plates to be used in clean rooms. Not a medical device / Not an IVD product

Product Detail
New
1LNY.1, Carl

1LNY.1, Carl

Sterile Sterile ready-to-use culture media plates for microbiological analysis. Diameter 90 mm Surface 63,6 cm 2 Ready-to-use and sterile Easy to use, reliable detection and simple evaluation Well applicable for microbiological analysis of samples With detailed instructions for use ROTI ® Plate90 are prepared culture media plates with a diameter of 90 mm. They are thus adapted to the size of membrane filters for assaying of low-germ fluids by membrane filtration method. They are also applicable for the microbiological analysis of samples in general. The germs of expected low-germ liquid samples are concentrated by membrane filtration. Afterwards, the membrane is placed on top of the medium and incubated. Using a membrane with a grid helps counting the resulting colonies. Our products are tested and approved exclusively for research and development. Samples which are expected to have a higher microbiological burden are prepared in a serial dilution. Afterwards, every dilution step is plated and incubated. The number of grown colonies is noted as result. ROTI ® Plate90 Sab4Cla acc. to Ph. Eur./USP, ISO 11133, ready-to-use, sterile, for microbiology Sabouraud 4% glucose agar with chloramphenicol is recommended by Ph. Eur. and USP for testing for the presence of fungi by the membrane filter method, and for counting fungal colonies on agar plates or by the dilution method (MPN method). This agar has a lower concentration of chloramphenicol than 1AX0, making it less inhibitory to contaminant bacteria.

Product Detail
New
37CH.1, Carl

37CH.1, Carl

Sterile Sterile ready-to-use culture media plates for microbiological analysis in isolators and cleanrooms. Diameter 90 mm Surface 63,6 cm 2 Ready-to-use and sterile Easy to use, reliable detection and simple evaluation Well applicable for microbiological analysis of samples With detailed instructions for use Triple packaged and Gamma irradiated Suitable for usage in isolators and cleanrooms ROTI ® Plate ICR are 90 mm ready-to-use nutrient trays that are triple-packed and gamma-irradiated, which enables them to be used in cleanrooms and isolators. With irradiation indicator and barcode labeling. ROTI ® Plate ICR TSA Penase acc. to Ph. Eur./USP, ISO 11133, ready-to-use, sterile, for microbiology TSA Penase Agar is recommended by Ph. Eur. and USP for the isolation and culture of microorganisms with penicillinase. The triple packaging enables the plates to be used in cleanrooms. Not a medical device / Not an IVD product

Product Detail
New
1ATT.1, Carl

1ATT.1, Carl

Sterile Sterile ready-to-use culture media plates for microbiological analysis. Diameter 90 mm Surface 63,6 cm 2 Ready-to-use and sterile Easy to use, reliable detection and simple evaluation Well applicable for microbiological analysis of samples With detailed instructions for use ROTI ® Plate90 are prepared culture media plates with a diameter of 90 mm. They are thus adapted to the size of membrane filters for assaying of low-germ fluids by membrane filtration method. They are also applicable for the microbiological analysis of samples in general. The germs of expected low-germ liquid samples are concentrated by membrane filtration. Afterwards, the membrane is placed on top of the medium and incubated. Using a membrane with a grid helps counting the resulting colonies. Our products are tested and approved exclusively for research and development. Samples which are expected to have a higher microbiological burden are prepared in a serial dilution. Afterwards, every dilution step is plated and incubated. The number of grown colonies is noted as result. ROTI ® Plate90 TSA acc. to Ph. Eur./USP, ISO 11133, ISO 21149:2017, ready-to-use, sterile, for microbiology The TSA Agar (Art. No. 1ATT) is certified according to Ph. Eur. and USP is suitable for determining the total bacterial count. Not a medical device / Not an IVD product

Product Detail
New
1K22.1, Carl

1K22.1, Carl

Sterile Sterile ready-to-use culture media plates for microbiological analysis. Diameter 90 mm Surface 63,6 cm 2 Ready-to-use and sterile Easy to use, reliable detection and simple evaluation Well applicable for microbiological analysis of samples With detailed instructions for use ROTI ® Plate90 are prepared culture media plates with a diameter of 90 mm. They are thus adapted to the size of membrane filters for assaying of low-germ fluids by membrane filtration method. They are also applicable for the microbiological analysis of samples in general. The germs of expected low-germ liquid samples are concentrated by membrane filtration. Afterwards, the membrane is placed on top of the medium and incubated. Using a membrane with a grid helps counting the resulting colonies. Our products are tested and approved exclusively for research and development. Samples which are expected to have a higher microbiological burden are prepared in a serial dilution. Afterwards, every dilution step is plated and incubated. The number of grown colonies is noted as result. ROTI ® Plate90 Mueller Hinton EUCAST, ready-to-use, sterile, for microbiology Mueller-Hinton Agar is a medium very rich in nutrients that was originally recommended for the isolation and development of gonococci and meningococci. It is used primarily for sensitivity testing of microorganisms. Not a medical device / Not an IVD product

Product Detail
New
1ATX.1, Carl

1ATX.1, Carl

Sterile Sterile ready-to-use culture media plates for microbiological analysis. Diameter 90 mm Surface 63,6 cm 2 Ready-to-use and sterile Easy to use, reliable detection and simple evaluation Well applicable for microbiological analysis of samples With detailed instructions for use ROTI ® Plate90 are prepared culture media plates with a diameter of 90 mm. They are thus adapted to the size of membrane filters for assaying of low-germ fluids by membrane filtration method. They are also applicable for the microbiological analysis of samples in general. The germs of expected low-germ liquid samples are concentrated by membrane filtration. Afterwards, the membrane is placed on top of the medium and incubated. Using a membrane with a grid helps counting the resulting colonies. Our products are tested and approved exclusively for research and development. Samples which are expected to have a higher microbiological burden are prepared in a serial dilution. Afterwards, every dilution step is plated and incubated. The number of grown colonies is noted as result. ROTI ® Plate90 CASO acc. to Ph. Eur./USP, ISO 11133, ready-to-use, sterile, for microbiology CASO-Agar (Art. No. 1ATX) is recommended by Ph. Eur . and USP for testing for the presence of bacteria using the membrane filter method, as well as for counting bacteria on agar plates or using the dilution method (MPN method). Containing two peptones obtained by enzymatic hydrolysis of casein and soy protein, this medium supports the growth of a great variety of microorganisms. Not a medical device / Not an IVD product

Product Detail
New
37CN.1, Carl

37CN.1, Carl

Sterile Sterile ready-to-use culture media plates for microbiological analysis in isolators and cleanrooms. Diameter 90 mm Surface 63,6 cm 2 Ready-to-use and sterile Easy to use, reliable detection and simple evaluation Well applicable for microbiological analysis of samples With detailed instructions for use Triple packaged and Gamma irradiated Suitable for usage in isolators and cleanrooms ROTI ® Plate ICR are 90 mm ready-to-use nutrient trays that are triple-packed and gamma-irradiated, which enables them to be used in cleanrooms and isolators. With irradiation indicator and barcode labeling. ROTI ® Plate ICR Sab4Cla acc. to Ph. Eur./USP, ISO 11133, ready-to-use, sterile, for microbiology Sabouraud 4% glucose agar with chloramphenicol is recommended by Ph. Eur. and USP for the isolation and cultivation of fungi. The triple packaging enables the plates to be used in cleanrooms. Not a medical device / Not an IVD product

Product Detail
New
37CP.1, Carl

37CP.1, Carl

Sterile Sterile ready-to-use culture media plates for microbiological analysis in isolators and cleanrooms. Diameter 90 mm Surface 63,6 cm 2 Ready-to-use and sterile Easy to use, reliable detection and simple evaluation Well applicable for microbiological analysis of samples With detailed instructions for use Triple packaged and Gamma irradiated Suitable for usage in isolators and cleanrooms ROTI ® Plate ICR are 90 mm ready-to-use nutrient trays that are triple-packed and gamma-irradiated, which enables them to be used in cleanrooms and isolators. With irradiation indicator and barcode labeling. ROTI ® Plate ICR SabDex acc. to Ph. Eur./USP, ISO 11133, ready-to-use, sterile, for microbiology Sabouraud dextrose agar is recommended by Ph. Eur. and USP for the isolation and cultivation of fungi. The triple packaging enables the plates to be used in cleanrooms. Not a medical device / Not an IVD product

Product Detail
New
1NAA.1, Carl

1NAA.1, Carl

Sterile Sterile ready-to-use culture media plates for microbiological analysis. Diameter 90 mm Surface 63,6 cm 2 Ready-to-use and sterile Easy to use, reliable detection and simple evaluation Well applicable for microbiological analysis of samples With detailed instructions for use ROTI ® Plate90 are prepared culture media plates with a diameter of 90 mm. They are thus adapted to the size of membrane filters for assaying of low-germ fluids by membrane filtration method. They are also applicable for the microbiological analysis of samples in general. The germs of expected low-germ liquid samples are concentrated by membrane filtration. Afterwards, the membrane is placed on top of the medium and incubated. Using a membrane with a grid helps counting the resulting colonies. Our products are tested and approved exclusively for research and development. Samples which are expected to have a higher microbiological burden are prepared in a serial dilution. Afterwards, every dilution step is plated and incubated. The number of grown colonies is noted as result. ROTI ® Plate90 MacCon ISO 11133, ready-to-use, sterile, for microbiology MacConkey agar is used for the subcultivation of Gram-negative enterobacterial colonies and for the determination of Escherichia coli . Bile salts and crystal violet are the selective agents and inhibit Gram-positive bacteria. Neutral red is the pH indicator that, when lactose is fermented and the pH drops, shows a colour change from neutral red to pink. Not a medical device / Not an IVD product

Product Detail
allied chemi
  • secure-payment
  • visa
  • american-express
  • master-card

© 2023 Copyright. All Rights Reserved. Unit 19, Euroway House, Roydsdale Way, Bradford, BD4 6SE, UK